Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 2 Task — Assign Link via procr-intf Data Module to Switch 1

This task administers a processor-interface data module for the x.25 connection to node 1. The data module associates a link number with a physical channel number and extension number for the PI port used for this connection.

Steps

Begin

 

 

 

 

 

> Open Data Module form — enter

a da n

 

 

 

 

 

 

 

add data-module next

 

 

 

 

 

Page 1 of 1

 

 

 

 

 

 

 

 

DATA MODULE

 

Data Extension: 4121

 

 

 

Name: _x.25 on link 2 to node-1__

Type: procr-intf

 

COS: 1

Maintenance Extension: 4191

Physical Channel: 02_

 

 

COR: 1

Destination Number: 8122102

ITC: Restricted

 

TN: 1

Establish Connection? n

Link: 2_

 

DTE/DCE: dce

Connected Data Module: _______

 

 

Enable Link: n

 

ABBREVIATED DIALING

 

 

 

 

 

List1: _______________

 

 

 

 

 

SPECIAL DIALING OPTION: ________________

 

ASSIGNED MEMBER (Station with a data extension button for this data module)

Ext

Name

 

 

 

 

1.

 

 

 

 

 

 

 

 

 

 

 

 

> Enter values.

 

 

 

 

 

 

 

 

 

 

 

Field

 

 

 

Conditions/Comments

 

 

 

 

 

 

 

Type:

 

 

 

This indicates the data-module type for this

 

 

 

 

 

connection.

 

 

 

 

 

Physical Channel:

 

This must be the same as the link number.

 

 

 

 

 

 

 

ITC:

 

 

 

Enter restricted. (unrestricted is used only for

 

 

 

 

 

wideband transmission.)

 

 

 

 

 

 

 

Link:

 

 

 

The link number must be in the range 1 –25 (for

 

 

 

 

 

R8si), not previously assigned on this switch.

 

 

 

 

 

 

 

Name:

 

 

 

Information-only; appears in list generated by the “list

 

 

 

 

 

data module” command.

 

 

 

 

 

 

 

 

COS:

 

 

 

 

 

 

 

 

 

 

The values for these fields will be specified by the

 

COR:

 

 

 

 

 

 

 

system administrator.

 

 

 

 

 

 

TN:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DTE/DCE:

 

 

The DTE/DCE assignments must be opposites on the

 

 

 

 

 

two ends of the connection. Use dte for node 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

1 of 2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

 

 

 

 

 

555-233-504 — Issue 1 — April 2000

 

 

CID: 77730

113

Page 133
Image 133
Lucent Technologies Release 8.2 manual Wideband transmission