Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 3 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module on Switch 3 for the ethernet connection to Switch 1. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data module next

 

 

Page 1 of x

 

DATA MODULE

 

Data Extension: 4531

Name: ethernet on link 3

BCC: 2

Type: ethernet

 

 

 

 

Port: 01a1017

 

 

 

 

Link: 3_

 

 

 

 

Network uses 1’s for broadcast addresses? y

 

 

 

 

 

 

 

> Enter values.

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

Type:

 

This indicates the data-module type for this connection.

 

 

 

 

 

Port:

 

In this example, the C-LAN circuit pack is in slot 01a10; the

 

 

 

ethernet connection is through port 17.

 

 

 

 

 

Link:

 

The link number must be in the range 1 – 25 (for R8si), not

 

 

 

previously assigned on this switch.

 

 

 

 

 

Name:

 

Information-only; appears in the “list data module” command list.

 

 

 

 

 

Network

 

Leave the default (y) if the private network contains only

 

uses 1’s for

 

DEFINITY switches and adjuncts. Set to n only if the network

 

broadcast

 

includes non-DEFINITY switches that use the 0’s method of

 

addresses?

 

forming broadcast addresses. See Appendix A, “Data Module -

 

 

 

type ethernet” for more information about this field.

 

 

 

 

 

 

> Submit the screen

End

 

 

Administration for Network Connectivity

120

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 140
Image 140
Lucent Technologies Release 8.2 manual 120 CID