Configuration 4: R8csi <—ISDN—> R8si Gateway

3 C-LAN Administration

<—ppp—> R8csi

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

Conditions/Comments

 

 

 

 

 

 

 

 

 

 

BCC:

 

Bearer Capability Class. This is a display-only field.

 

 

 

 

 

 

 

 

 

 

COS

 

 

 

 

 

 

 

 

The values for these fields will be specified by the system

 

 

 

COR:

 

 

 

 

 

administrator.

 

 

 

 

 

 

 

 

 

 

TN:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Node Name:

 

The node name for the interface defined by this data module.

 

 

 

 

 

This must be a name entered on the Node Names screen.

 

 

 

 

 

 

 

 

 

Establish

 

y means that this switch will be responsible for call setup for this

 

 

 

Connection?

 

connection. Enter n when administering the data module for

 

 

 

 

 

Switch 3.

 

 

 

 

 

 

 

 

 

 

Destination

 

Trunk access code (79) plus extension of data module on node-3

 

 

 

Digits:

(2801).

 

 

 

 

 

 

 

 

 

 

Destination

 

Name of the node at the far end of this connection. This must be a

 

 

 

Node Name:

 

name entered on the Node Names screen

 

 

 

 

 

 

 

 

 

CHAP?

 

This field enables/disables the Challenge Handshake

 

 

 

 

 

Authentication Protocol security mechanism on this link. If you

 

 

 

 

 

enter y, the system will prompt for a CHAP secret (password).

 

 

 

 

 

 

 

 

 

 

 

 

 

2 of 2

 

 

 

 

 

 

 

 

 

> Submit the screen

 

 

 

End

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

128

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 148
Image 148
Lucent Technologies Release 8.2 manual Node Name Name entered on the Node Names screen