Configuration 3: R8si<—x.25 —> R8r Gateway

3 C-LAN Administration

<—ethernet—> R8si

 

Switch 1 Task — Assign Link via ethernet Data Module to the LAN

This task administers an ethernet data module for ethernet connections. The data module associates a link number with a port address, extension number, and node name for the C-LAN port used for this connection.

Steps

Begin

> Open Data Module form — enter a da n

add data module next

Page 1 of x

 

DATA MODULE

Data Extension: 3391

Name: ethernet on link 3 BCC: 2

Type: ethernet

 

Port: 01b0117

 

Link: 3

 

Network uses 1’s for broadcast addresses? y

 

 

 

> Enter values.

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

Type:

This indicates the data-module type for this connection.

 

 

 

 

Port:

In this example, the C-LAN circuit pack is in slot 01b01; the

 

 

ethernet connection is through port 17.

 

 

 

 

Link:

The link number must be in the range 1 – 33 (for R8r).

 

 

 

 

Name:

Information-only; appears in list generated by the “list data

 

 

module” command.

 

 

 

 

Network

Leave the default (y) if the private network contains only

 

uses 1’s for

DEFINITY switches and adjuncts. Set to n only if the network

 

broadcast

includes non-DEFINITY switches that use the 0’s method of

 

addresses?

forming broadcast addresses. See Appendix A, “Data Module -

 

 

type ethernet” for more information about this field.

 

 

 

> Submit the screen

End

 

 

Administration for Network Connectivity

108

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 128
Image 128
Lucent Technologies Release 8.2 manual Add data module next