Appendix 1: Ademco Contact ID Report Code List

CID#

Reporting Code

Programming

 

 

Value

 

 

 

Medical Alarms - 100

 

100

Medical alarm

01

101

Pendant transmitter

02

102

Fail to report in

03

 

 

Fire Alarms - 110

 

110

Fire alarm

04

111

Smoke

05

112

Combustion

06

113

Water flow

07

114

Heat

08

115

Pull station

09

116

Duct

0A

117

Flame

0B

118

Near alarm

0C

 

 

Panic Alarms - 120

 

120

Panic alarm

0D

121

Duress

0E

122

Silent

0F

123

Audible

10

124

Duress - Access granted

11

125

Duress - Egress granted

12

 

 

Burglar Alarms - 130

 

130

Burglary

13

131

Perimeter

14

132

Interior

15

133

24-hour

16

134

Entry/Exit

17

135

Day/Night

18

136

Outdoor

19

137

Tamper

1A

138

Near alarm

1B

139

Intrusion verified

1C

 

 

General Alarms - 140

 

140

General alarm

1D

141

Polling loop open

1E

142

Polling loop short

1F

143

Expansion module failure

20

144

Sensor tamper

21

145

Expansion module tamper

22

146

Silent burglary

23

147

Sensor supervision failure

24

 

 

24-hour Non-burglary - 150 and 160

 

150

24-hour non-burglary

25

151

Gas detected

26

152

Refrigeration

27

153

Loss of heat

28

 

 

 

CID#

Reporting Code

Programming

 

 

Value

 

 

 

154

Water leakage

29

155

Foil break

2A

156

Day trouble

2B

157

Low bottled gas level

2C

158

High temperature

2D

159

Low temperature

2E

161

Loss of air flow

2F

162

Carbon monoxide detected

30

163

Tank level

31

 

 

Fire Supervisory - 200 and 210

 

200

Fire supervisory

32

201

Low water pressure

33

202

Low CO2

34

203

Gate valve sensor

35

204

Low water level

36

205

Pump activated

37

206

Pump failure

38

 

 

System Troubles - 300 and 310

 

300

System trouble

39

301

AC loss

3A

302

Low system battery

3B

303

RAM checksum bad

3C

304

ROM checksum

3D

305

System reset

3E

306

Panel program changed

3F

307

Self-test failure

40

308

System shutdown

41

309

Battery test failure

42

310

Ground fault

43

311

Battery missing/dead

44

312

Power supply over current limit

45

313

Engineer reset

46

 

 

Sounder/Relay Troubles - 320

 

320

Sounder/relay

47

321

Bell 1

48

322

Bell 2

49

323

Alarm relay

4A

324

Trouble relay

4B

325

Reversing relay

4C

326

Notification appliance chk. #3

4D

327

Notification appliance chk. #4

4E

 

 

System Peripheral Troubles - 330 and 340

 

330

System peripheral

4F

331

Polling loop open

50

332

Polling loop short

51

333

Expansion module failure

52

334

Repeater failure

53

 

 

 