CID# | Reporting Code | Programming |
|
| Value |
|
|
|
335 | Local printer paper out | 54 |
336 | Local printer failure | 55 |
337 | Expansion module DC loss | 56 |
338 | Expansion module low battery | 57 |
339 | Expansion module reset | 58 |
341 | Expansion module tamper | 59 |
342 | Expansion module AC loss | 5A |
343 | Expansion module | 5B |
344 | RF receiver jam detect | 5C |
|
| |
Communication Troubles - 350 and 360 |
| |
350 | Communication | 5D |
351 | Telco 1 fault | 5E |
352 | Telco 2 fault | 5F |
353 | Long range radio | 60 |
354 | Fail to communicate | 61 |
355 | Loss of radio supervision | 62 |
356 | Loss of central polling | 63 |
357 | Long range radio VSWR problem | 64 |
|
| |
Protection Loop Troubles - 370 |
| |
370 | Protection loop | 65 |
371 | Protection loop open | 66 |
372 | Protection loop short | 67 |
373 | Fire trouble | 68 |
374 | Exit error alarm | 69 |
375 | Panic zone trouble | 6A |
376 | 6B | |
377 | Swinger trouble | 6C |
378 | 6D | |
|
| |
Sensor Troubles - 380 and 390 |
| |
380 | Sensor trouble | 6E |
381 | Loss of supervision - RF | 6F |
382 | Loss of supervision - RPM | 70 |
383 | Sensor tamper | 71 |
384 | RF transmitter low battery | 72 |
385 | Smoke detector Hi sensitivity | 73 |
386 | Smoke detector Low sensitivity | 74 |
387 | Intrusion detector Hi sensitivity | 75 |
388 | Intrusion detector Low sensitivity | 76 |
389 | Sensor | 77 |
391 | Sensor watch trouble | 78 |
392 | Drift compensation error | 79 |
393 | Maintenance alert | 7A |
|
| |
Open/Close - 400 |
| |
400 | Open/Close | 7B |
401 | Open/Close by user | 7C |
402 | Group open/close | 7D |
403 | Automatic open/close | 7E |
406 | Cancel | 7F |
407 | Remote arm/disarm | 80 |
|
|
|
CID# | Reporting Code | Programming |
|
| Value |
|
|
|
408 | Quick arm | 81 |
409 | Keyswitch open/close | 82 |
|
| |
Remote Access - 410 |
| |
411 | Call back request made | 83 |
412 | Success - download access | 84 |
413 | Unsuccessful access | 85 |
414 | System shutdown | 86 |
415 | Dialer shutdown | 87 |
416 | Successful upload | 88 |
|
| |
Access Control - 420 and 430 |
| |
421 | Access denied | 89 |
422 | Access report by user | 8A |
423 | Forced access | 8B |
424 | Egress denied | 8C |
425 | Egress granted | 8D |
426 | Access door propped open | 8E |
427 | Access point door status monitor trouble | 8F |
428 | Access point request to exit | 90 |
429 | Access program mode entry | 91 |
430 | Access program mode exit | 92 |
431 | Access threat level change | 93 |
432 | Access relay/trigger fail | 94 |
433 | Access RTE shunt | 95 |
434 | Access DSM shunt | 96 |
|
| |
Arming - 440 and 450 |
| |
441 | Armed Stay | 97 |
442 | Keyswitch armed Stay | 98 |
450 | Exception open/close | 99 |
451 | Early open/close | 9A |
452 | Late open/close | 9B |
453 | Failed to open | 9C |
454 | Failed to close | 9D |
455 | 9E | |
456 | Partial arm | 9F |
457 | Exit error (user) | A0 |
458 | User on premises | A1 |
459 | Recent close | A2 |
|
| |
System - 460 |
| |
461 | Wrong code entry | A3 |
462 | Legal code entry | A4 |
463 | A5 | |
464 | A6 | |
465 | Panic alarm reset | A7 |
466 | Service on/off premises | A8 |
|
| |
Sounder Relay Disabled - 520 |
| |
520 | Sounder/Relay disabled | A9 |
521 | Bell 1 disabled | AA |
522 | Bell 2 disabled | AB |
523 | Alarm relay disabled | AC |
524 | Trouble relay disabled | AD |
|
|
|
Paradox Magellan Systems | 35 |