24Hr. Gas Zones
Sections [001] to [016]: Zones 1 to 16,
When a 24Hr. Gas zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Gas alarm.
24Hr. Heat Zones
Sections [001] to [016]: Zones 1 to 16,
When a 24Hr. Heat zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Heat alarm.
24Hr. Water Zones
Sections [001] to [016]: Zones 1 to 16,
When a 24Hr. Water zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Water alarm.
24Hr. Freeze Zones
Sections [001] to [016]: Zones 1 to 16,
When a 24Hr. Freeze zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Freeze alarm.
Zone Options
Sections [001] to [016] represent zones 1 through 16 respectively as demonstrated in Figure 16 on page 13. After entering the
Auto-zone Shutdown
Sections [001] to [016]: Zones 1 to 16; Option [1]
Option [1] OFF
If, in a single armed period, the number of alarms generated by a zone with the Auto Zone Shutdown option enabled exceeds the number defined by the Auto Zone Shutdown Counter, the console will no longer generate an alarm for that zone. The Auto Zone Shutdown Counter resets every time the system is armed.
Auto-zone Shutdown Counter
Section [067]: 001 to 015 alarms; 000 = Disabled; Default = 5 alarms
Enter the desired limit into section [067] to program the
Bypass Option
Section [001] to [016]: Zones 1 to 16; Option [2]
Option [2] OFF =Bypass option disabled
Option [2] ON =Selected zone is bypass enabled (default)
When a user uses the Bypass Programming feature, only zones with the Bypass option enabled can be programmed as bypassed.
Fire zones cannot be programmed with the Bypass option because the console will not bypass a Fire zone.
Alarm Types
Sections [001] to [016]: Zones 1 to 16; Options [4] and [5]
When an alarm condition occurs, the console can be programmed to react as shown in Table 2 on page 15.
|
| Table 2: Alarm Type Options | |
Options |
| Description | |
[4] | [5] |
|
|
|
|
|
|
OFF | OFF |
| Audible steady alarm (default) |
|
|
| When the conditions for an alarm have been |
|
|
| met, the control panel can transmit the |
|
|
| appropriate Zone Alarm report code (see |
|
|
| page 24) and provides a steady output for the |
|
|
| |
OFF | ON |
| Audible pulsed alarm |
|
|
| When the conditions for an alarm have been |
|
|
| met, Magellan can transmit the appropriate Zone |
|
|
| Alarm report code (see page 24) and provides a |
|
|
| pulsed output (see Figure 17 on page 14) for the |
|
|
| |
ON | OFF |
| Silent alarm |
|
|
| When the conditions for an alarm are met, the |
|
|
| control panel can transmit the appropriate Zone |
|
|
| Alarm report code (see page 24) and will not |
|
|
| activate the control panel’s bell output. The |
|
|
| appropriate ARM or STATUS LED on the keypads |
|
|
| will flash to indicate an alarm and the user will |
|
|
| still have to disarm the system. |
ON | ON |
| Report only |
|
|
| When the conditions for an alarm have been |
|
|
| met, the control panel can transmit the |
|
|
| appropriate Zone Alarm report code (see |
|
|
| page 24). The system will not have to be |
|
|
| disarmed. |
|
|
|
|
The Alarm Type options cannot be programmed for Fire zones. Fire zones are automatically programmed with an audible pulsed alarm. This cannot be altered.
Intellizone
Sections [001] to [016]: Zones 1 to 16; option [6]
Option [6] OFF =Intellizone disabled (default)
Option [6] ON =Intellizone enabled
This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the console does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. If any of the following conditions occur during this period, the panel will generate an alarm:
•During the Intellizone Delay, a second zone has caused an alarm.
•During the Intellizone Delay, the zone in alarm has restored (closed) and
•The zone in alarm is still open after the Intellizone Delay has elapsed.
Paradox Magellan Systems | 15 |