Magellan MG-6060 Zone Options, 24Hr. Gas Zones, 24Hr. Heat Zones, 24Hr. Water Zones, Alarm Types

Models: MG-6060

1 48
Download 48 pages 39.41 Kb
Page 17
Image 17
24Hr. Gas Zones

24Hr. Gas Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 012

When a 24Hr. Gas zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Gas alarm.

24Hr. Heat Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 013

When a 24Hr. Heat zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Heat alarm.

24Hr. Water Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 014

When a 24Hr. Water zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Water alarm.

24Hr. Freeze Zones

Sections [001] to [016]: Zones 1 to 16, 3-digit # = 015

When a 24Hr. Freeze zone opens, whether it is armed or disarmed, the console will immediately generate an alarm. The SIA FSK reporting format includes specific report codes to identify the alarm as a Freeze alarm.

Zone Options

Sections [001] to [016] represent zones 1 through 16 respectively as demonstrated in Figure 16 on page 13. After entering the 3-digit Zone Definition (see Zone Definitions on page 13), select one or more of the following Zone Options by using the Feature Select Programming Method (see page 11):

Auto-zone Shutdown

Sections [001] to [016]: Zones 1 to 16; Option [1]

Option [1] OFF =Auto-zone Shutdown disabled Option [1] ON =Auto-zone Shutdown enabled (default)

If, in a single armed period, the number of alarms generated by a zone with the Auto Zone Shutdown option enabled exceeds the number defined by the Auto Zone Shutdown Counter, the console will no longer generate an alarm for that zone. The Auto Zone Shutdown Counter resets every time the system is armed.

Auto-zone Shutdown Counter

Section [067]: 001 to 015 alarms; 000 = Disabled; Default = 5 alarms

Enter the desired limit into section [067] to program the Auto-zone Shutdown Counter.

Bypass Option

Section [001] to [016]: Zones 1 to 16; Option [2]

Option [2] OFF =Bypass option disabled

Option [2] ON =Selected zone is bypass enabled (default)

When a user uses the Bypass Programming feature, only zones with the Bypass option enabled can be programmed as bypassed.

Fire zones cannot be programmed with the Bypass option because the console will not bypass a Fire zone.

Alarm Types

Sections [001] to [016]: Zones 1 to 16; Options [4] and [5]

When an alarm condition occurs, the console can be programmed to react as shown in Table 2 on page 15.

 

 

Table 2: Alarm Type Options

Options

 

Description

[4]

[5]

 

 

 

 

 

 

OFF

OFF

 

Audible steady alarm (default)

 

 

 

When the conditions for an alarm have been

 

 

 

met, the control panel can transmit the

 

 

 

appropriate Zone Alarm report code (see

 

 

 

page 24) and provides a steady output for the

 

 

 

on-board siren.

OFF

ON

 

Audible pulsed alarm

 

 

 

When the conditions for an alarm have been

 

 

 

met, Magellan can transmit the appropriate Zone

 

 

 

Alarm report code (see page 24) and provides a

 

 

 

pulsed output (see Figure 17 on page 14) for the

 

 

 

on-board siren.

ON

OFF

 

Silent alarm

 

 

 

When the conditions for an alarm are met, the

 

 

 

control panel can transmit the appropriate Zone

 

 

 

Alarm report code (see page 24) and will not

 

 

 

activate the control panel’s bell output. The

 

 

 

appropriate ARM or STATUS LED on the keypads

 

 

 

will flash to indicate an alarm and the user will

 

 

 

still have to disarm the system.

ON

ON

 

Report only

 

 

 

When the conditions for an alarm have been

 

 

 

met, the control panel can transmit the

 

 

 

appropriate Zone Alarm report code (see

 

 

 

page 24). The system will not have to be

 

 

 

disarmed.

 

 

 

 

The Alarm Type options cannot be programmed for Fire zones. Fire zones are automatically programmed with an audible pulsed alarm. This cannot be altered.

Intellizone

Sections [001] to [016]: Zones 1 to 16; option [6]

Option [6] OFF =Intellizone disabled (default)

Option [6] ON =Intellizone enabled

This feature reduces the possibility of false alarms. When a zone with the Intellizone option opens, the console does not immediately generate an alarm. First it triggers the Intellizone Delay Timer. If any of the following conditions occur during this period, the panel will generate an alarm:

During the Intellizone Delay, a second zone has caused an alarm.

During the Intellizone Delay, the zone in alarm has restored (closed) and re-occurred (opened).

The zone in alarm is still open after the Intellizone Delay has elapsed.

Paradox Magellan Systems

15

Page 17
Image 17
Magellan MG-6060 Zone Options, 24Hr. Gas Zones, 24Hr. Heat Zones, 24Hr. Water Zones, 24Hr. Freeze Zones, Auto-zoneShutdown