Magellan MG-6060 Alarm Options, Bell Cut-offTimer, Wireless Transmitter Supervision Options

Models: MG-6060

1 48
Download 48 pages 39.41 Kb
Page 24
Image 24
Alarm Options

Alarm Options

Bell Cut-off Timer

Section [063]: 001 to 255 minutes; 000 = Disabled; Default = 4 minutes

After an audible alarm, the siren will stop upon disarming of the system or when the Bell Cut-Off timer has elapsed, whichever comes first.

Wireless Transmitter Supervision Options

Section [094]: Options [6] and [7]

This feature determines how the Magellan console will react to a Supervision Loss trouble. Table 5 shows the different supervision loss combinations available and how the system will react when armed or disarmed.

Table 5: Wireless Transmitter Supervision Options

Options

Description

[6]

[7]

 

 

 

 

OFF

OFF

Wireless transmitter supervision disabled

OFF

ON

Trouble only (default)

 

 

System armed or disarmed: If a supervision loss

 

 

occurs on a zone, the console will display a trouble on

 

 

the LCD screen and send a report to the central

 

 

monitoring station.

ON

OFF

Audible alarm when armed

 

 

System armed: If a supervision loss occurs on a zone,

 

 

the console will follow the zone's Alarm Types setting

 

 

(see page 15).

 

 

System disarmed: If a supervision loss occurs on a

 

 

zone, the console will display a trouble on the LCD

 

 

screen.

ON

ON

Audible alarm

 

 

System armed: If a supervision loss occurs on a zone,

 

 

the console will follow the zone's Alarm Types setting

 

 

(see page 15).

 

 

System disarmed: It functions the same as Trouble

 

 

Only setting, except it will also generate an audible

 

 

alarm.

 

 

 

Supervision Bypass Options

Section [094]: Option [8]

Option [8] OFF =No Supervision Loss if detected on a Bypassed Zone (default)

Option [8] ON =Generate Supervision Loss if detected on a Bypassed Zone

When option [8] is OFF, the Wireless Transmitter Supervision Options (page 22) will follow the zone's bypass definition. This means the console will not perform any action if a Supervision Loss occurs on a bypassed zone.

When option [8] is ON, the Wireless Transmitter Supervision Options (page 22) will ignore the bypass definition. This means the console will generate an incident as per the set Wireless Transmitter Supervision Option if a supervision loss occurs on a bypassed zone.

Tamper Recognition Options

Section [094]: Options [3] and [4]

This feature determines how the Magellan console will react to a zone tamper. Table 6 shows the different tamper recognition combinations available and how the system will react when armed or disarmed.

 

 

Table 6: Tamper Recognition Options

Options

 

Description

[3]

[4]

 

 

 

 

 

 

OFF

OFF

 

Tamper recognition disabled (default)

OFF

ON

 

Trouble only

 

 

 

System armed or disarmed: If a tamper wiring failure

 

 

 

occurs on a zone, the console will follow the zone's

 

 

 

Alarm Types setting (see page 15) and send a report

 

 

 

to the central monitoring station.

ON

OFF

 

Audible alarm when armed

 

 

 

System armed: If a tamper failure occurs on a zone,

 

 

 

the console will follow the zone's Alarm Types setting

 

 

 

(see page 15).

 

 

 

System disarmed: If a tamper failure occurs on a

 

 

 

zone, the console will follow the zone's Alarm Types

 

 

 

setting (see page 15) and send a report to the central

 

 

 

monitoring station.

ON

ON

 

Audible alarm

 

 

 

System armed: If a tamper failure occurs on a zone,

 

 

 

the console will follow the zone's Alarm Types setting

 

 

 

(see page 15).

 

 

 

System disarmed: It functions the same as Trouble

 

 

 

Only setting, except it will also generate an audible

 

 

 

alarm.

 

 

 

 

Tamper Bypass Options

Section [094]: Option [5]

Option [5] OFF =Ignore any tampers detected on a bypassed zone (default)

Option [5] ON = Generate tamper if detected on a bypassed zone

When option [5] is ON, the Tamper Recognition feature (page 22) will ignore the zone’s bypass definition. This means the console will generate an incident as per the set Tamper Recognition option if a tamper occurs on a bypassed zone.

When option [5] is OFF, the Tamper Recognition feature (page 22) will follow the zone's bypass definition. This means the console will ignore any tampers that occur on a bypassed zone.

Check-in Supervision Options

Section [103]: Options [1] to [8]; Zones 1 to 8; Default: All ON

Section [104]: Options [1] to [8]; Zones 9 to 16; Default: All ON

If enabled, Magellan can wait for each of its assigned wireless transmitters to send a status signal within a specified time (see Check-in Supervision Time on page 23) to confirm their

22

Reference & Installation Manual

Page 24
Image 24
Magellan MG-6060 Alarm Options, Bell Cut-offTimer, Wireless Transmitter Supervision Options, Tamper Recognition Options