Follow/Stay Zones
Sections [001] to [016]: Zones 1 to 16,
Follow/Stay zones function as follows:
•All zones defined as Follow/Stay zones become Follow zones (refer to Follow Zones on page 13) when the Magellan system is Regular armed.
•All zones defined as Follow/Stay zones become Stay zones when the Magellan system is Stay or Instant armed.
Instant Zones
Sections [001] to [016]: Zones 1 to 16,
When an armed Instant zone opens, the console immediately generates an alarm. Instant zones are commonly used for windows, patio doors, skylights and other perimeter type zones.
Instant/Stay Zones
Sections [001] to [016]: Zones 1 to 16,
Instant/Stay zones function as follows:
•All zones defined as Instant/Stay zones become Instant zones (refer to Instant Zones on page 14) when the Magellan system is Regular armed.
•All zones defined as Instant/Stay zones become Stay zones when the Magellan system is Stay or Instant armed.
Standard 24Hr. Fire Zones
Sections [001] to [016]: Zones 1 to 16,
Whenever a Standard 24Hr. Fire Zone opens, whether it is armed or disarmed, the console will generate the following:
•The console can send the corresponding Alarm Report Code from sections [187] to [190].
•Alarms are always audible regardless of other settings. Fire alarms generate an intermittent (pulsed) bell/siren output signal as shown in Figure 17 on page 14.
Figure 17: Bell/Siren Output during a Fire Alarm
Delayed Fire Zones
Sections [001] to [016]: Zones 1 to 16,
When a Delayed 24Hr. Fire Zone opens, whether it is armed or disarmed, the console will react as shown in Figure 18 on page
14.Delayed 24Hr. Fire Zones are commonly used in residential homes where a smoke detector often generates false alarms (i.e. burning bread, etc.).
Figure 18: Delayed Fire Zone
24Hr. Burglary Zones
Sections [001] to [016]: Zones 1 to 16,
Whenever a 24Hr. Burglary Zone opens, whether the system is armed or disarmed, the console will immediately generate an alarm.
24Hr. Hold-up Zones
Sections [001] to [016]: Zones 1 to 16,
When a 24Hr.
24Hr. Buzzer Zones
Sections [001] to [016]: Zones 1 to 16,
This zone definition is particularly useful when a user wishes to be notified when something such as a safe or locker within the home has been accessed (i.e. a child accessing a valuable collection). This zone definition functions as follows:
•Whenever a 24Hr. Buzzer Zone opens, whether the console is armed or disarmed, the console sets off the keypads’ buzzers to indicate that the zone was breached.
•The console will report the alarm, but will not enable the bell/ siren output.
•Enter any valid access code on the keypad to stop the buzzer.
14 | Reference & Installation Manual |