Hardwire Zone Connections

Hardwire Zone Connections

Magellan comes with two on-board hardwire zones. You can connect hardwire detection devices such as door contacts to Magellan’s zone terminals. Connect the detection devices as shown in Figure 6 on page 8. Please note the following:

Section [095] options [1] and [2] must be enabled in order to use the two on-board hardwire zones. See Zones 15 and 16 become Hardwire Zones on page 16 for more information.

After connecting the detection devices, the zones must be defined. See Zone Programming on page 13 for more information.

The hardwire zones follow the console’s EOL and tamper definitions.

Though any hardwire detection device can be connected to Magellan’s on-board hardwire zone inputs, it is recommended that only devices that do not require a power source (i.e. standard door contacts) be connected. Since Magellan has no power supply, an external power supply would have to be connected in order to power hardwire detection devices that do require a power source.

Figure 6: Hardwire Zone Connections

Back view of the Magellan console.

Figure 7: Connecting to WInLoad

Back view of the

Magellan console.

4- to 10-pin cable (supplied with Figure 6: Hardwire Zone Connections

the 306 Adapter)

4-pin

connector

cable

306 Adapter

 

Standard

Computer

DB-9 cable

(9-pin serial cable)

containing

 

 

 

 

WinLoad

 

 

software

 

 

Hardwire zone 2 (zone 16)

1K9 EOL

Hardwire zone 1 (zone 15)

1K9 EOL

WinLoad Connection

The Magellan console can be programmed and monitored through the WinLoad Installer Upload/Download Software for Windows®. WinLoad allows for remote or on-site uploading and downloading using most standard modems. It also allows for advanced printing of reports and supports several languages simultaneously. Connect Magellan to a computer containing the WinLoad software as shown in Figure 7 on page 8.

Refer to the WinLoad’s Online Help for more information on WinLoad.

UIP-256 Universal In-Field Programmer Connection

Magellan’s firmware can be upgraded locally using the UIP-256 Universal In-Field Programmer. The UIP-256 includes proprietary PC software, cables to interconnect Magellan and a PC, as well as two 9V batteries. Connect the UIP-256 as shown in Figure 8 on page 8.

Refer to the Universal In-Field Programmer (UIP-256) Instructions for more information.

Figure 8: Connecting the UIP-256

Connect the 10-pin cable of the UIP-256 to

the 10-pin connector of

the Magellan console.Back view of the Magellan console.

UIP-256

Standard

Universal In-Field

DB-9 cable

Programmer

(9-pin serial cable)

 

Download latest

Magellan

firmware from

www.paradox.ca

8

Reference & Installation Manual

Page 10
Image 10
Magellan MG-6060 Hardwire Zone Connections, WinLoad Connection, UIP-256Universal In-FieldProgrammer Connection