Arming and Disarming
Regular Arming Switches to Stay Arming
Section [092]: Option [4]
Option [4] OFF = Switch to Stay arming disabled (default) Option [4] ON = Switch to Stay arming enabled
If a user Regular arms the system, but does not exit through (open and close) an Entry Delay zone during the Exit Delay, the console can be programmed to switch from Regular arming to Stay arming.
Regular Arming Switches to Force Arming
Section [092]: Option [5]
Option [5] OFF = Regular arming switches to Force arming disabled
Option [5] ON = Regular arming switches to Force arming enabled (default)
With this feature enabled, the console will always Force arm instead of Regular arm when a valid User code is entered. In installations where the User must always Force arm when leaving the protected area, this feature allows users to Force arm after entering their User code.
Stay Arming Switches to Force Arming
Section [092]: Option [6]
Option [6] OFF = Stay arming switches to Force arming disabled (default)
Option [6] ON = Stay arming switches to Force arming enabled
With this feature enabled, the console will always Force arm and Stay arm when a valid User code is entered even if there are perimeter zones open.
Timed Auto-Arming
Section [092]: Option [1]
Option [1] OFF = Timed
The Magellan system can be programmed to arm every day at the time specified by the
•The
•Any open zones detected when the system is
•The console will enter a
•Once the system has successfully armed, the console can transmit the Timed
Example: To automatically arm the system everyday at 6:15PM, enable section [092] option [1] to activate Timed
Auto-arm Timer
Section [085]
Program the time (use the
No Movement Auto-Arming
Section [092]: Option [2]
Option [2] OFF = No Movement
If no movement occurs in a zone's protected area for the period specified by the No Movement Timer (see below), the console can automatically arm the system.
•The
•Any open zones detected when the system is
•Upon arming, the console will transmit the No Movement report code if programmed in section [124].
•Regardless of whether the system was successfully armed or not, the console will always transmit the No Movement report code if programmed in section [124].
•If No Movement
Example: To arm the system whenever there is no movement for a period of 4 hours, enable section [092] option [2] (No Movement
No Movement Timer
Section [064]: 001 to 255 x 15 minutes; 000 = Disabled; Default = 000
Program the interval of time without movement you wish the console to wait before arming and/or sending the No Movement report code. If No Movement
Auto-Arming Options
Section [092]: Option [3]
Option [3] OFF =
When using Timed
20 | Reference & Installation Manual |