H.323 Trunk Administration

2 H.323 Trunks

Task 6 — Modify signaling group

This task modifies the signaling group form to add a trunk group number to the Trunk

Group for Channel Selection field.

Task 6 Steps

 

Begin

 

 

 

 

 

 

> Busy out the signaling group — enter

bu sig 3

 

 

 

> Open the Signaling Group form — enter ch sig 3

 

 

 

 

 

 

 

 

 

 

 

 

change signaling-group 3

 

 

Page

1 of 5

 

 

SIGNALING GROUP

 

 

 

 

Group Number: 3

 

Group Type: h.323

Max number of NCA TSC: 0

 

 

 

 

 

 

 

 

 

 

 

 

Max number of CA TSC: 0

Trunk Group for Channel Selection: 3

Trunk Group for NCA TSC:

 

 

 

 

Supplementary Service Protocol: a

 

 

 

 

Near-end Node Name: clan-a1

Far-end Node Name: clan-b1

 

 

 

 

 

 

 

 

 

 

 

Near-end Listen Port: 1720

Far-end Listen Port: 1720

 

 

 

 

 

 

 

LRQ Required? n

Calls Share IP Signaling Connection? n

 

 

 

 

 

Bypass If IP Threshold Exceeded? n

 

 

 

 

 

 

 

 

 

 

 

> Enter values

 

 

 

 

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

 

Trunk Group for Channel

Enter the trunk group number. If there is more than

 

Selection

one trunk group assigned to this signaling group, the

 

 

 

 

 

group entered in this field will be the one that can

 

 

 

 

 

accept incoming calls.

 

 

 

 

 

 

 

 

 

 

> Submit the screen

 

 

 

 

 

 

> Release the signaling group — enter

rel sig 3.

 

 

 

End

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Administration for Network Connectivity

48

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 68