Lucent Technologies Release 8.2 manual To CMS

Models: Release 8.2

1 524
Download 524 pages 28.9 Kb
Page 100
Image 100

Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

Switch 1 Task — Assign Processor Channels

This task associates data links (hardware) with processor channels (software) on the node 1 switch.

Steps

Begin

> Open the Processor Channel Assignment form — enter ch com p

change communications-interface processor-channels

Page 1 of X

PROCESSOR CHANNEL ASSIGNMENT

Proc

 

 

 

 

Gtwy

Interface

Destination

Session

Mach

Chan Enable Appl.

To Mode

Link/Chan

Node

Port

Local/Remote

ID

1:

y

mis____

s

2_

5001__

node-2____

0____

1 _

1_

__

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2:

n

_______

_

__

_____

__________

0____

___

___

__

3:

n

_______

_

__

_____

__________

0____

___

___

__

4:

n

_______

_

__

_____

__________

0____

___

___

__

:

 

 

 

 

 

 

 

 

 

 

 

 

 

12:

y

dcs ___

s

2_

5003__ node-5____

0____

12_

21_

2_

:

 

 

 

 

 

 

 

 

 

 

 

 

 

64:

n

 

________

_

__

_____

__________

0____

___

___

__

> Enter values

Field

Conditions/Comments

Processor Channel 1: (connection to CMS)

Enable

Set to y.

 

 

Appl.

Enter mis for the CMS connection on Processor Channel 1.

 

 

Mode

Set the Mode to s (“server”) on both switches for connections

 

to CMS.

 

 

Interface Link

This must match the link number assigned on the node-1 data

 

module screen.

 

 

Interface Chan

For TCP/IP, interface channel numbers are in the range 5000

 

– 64500.

 

The recommended values are: 5001 for CMS, 5002 for Intuity

 

AUDIX, and 5003 for DCS connections that are not

 

gateways. These three values should be reused for multiple

 

instances of these applications; for example, if there are two

 

Intuity AUDIX’s, use 5002 for both; or if there are four

 

DEFINITY ECS’s, use 5003 for all four. The combination of

 

Link, Interface Channel, and Mach ID must be unique.

 

The recommended values for gateway switches is 6001–6099.

 

The interface channel number must be unique for each

 

gateway.

 

 

 

1 of 3

 

 

Administration for Network Connectivity

80

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 100
Image 100
Lucent Technologies Release 8.2 manual To CMS