Configuration 4: R8csi <—ISDN—> R8si Gateway

3 C-LAN Administration

<—ppp—> R8csi

 

 

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Destination

Name of the far-end node for this channel. This must be a name

 

Node

entered on the Node Names screen. For ppp connections, it must

 

 

match the Destination Node Name entered on the ppp Data

 

 

Module screen.

 

 

 

 

 

Destination

A value of 0 allows any available interface channel on the

 

Port

destination node to be used for this connection. The Interface

 

 

Channel number for this connection on the Switch-3 Processor

 

 

Channel screen must also be set to 0.

 

 

 

 

Session -

The Local and Remote Session numbers can be any value

 

Local

between 1 and 256 (si model) or 384 (r model), but they must be

 

 

consistent between endpoints. For each connection, the Local

 

Session -

 

Session number on this switch must equal the Remote Session

 

Remote

 

number on the remote switch and vice versa.

 

 

 

 

It is allowed, and sometimes convenient, to use the same number

 

 

for the Local and Remote Session numbers. It is allowed, but not

 

 

recommended, to use the same Session numbers for two or more

 

 

connections.

 

 

 

 

 

Mach ID

Destination switch ID identified on the dial plan of the

 

 

destination switch.

 

 

 

 

 

Processor Channel 14: (Gateway between Switch 2 and Switch 3)

Enable

Set to y.

 

 

Appl.

Set to gateway for conversion between ISDN and TCP/IP.

 

 

Mode

Node-1 is the “server” for this session. Set node-3 to “client”

 

(c).

 

 

Interface Link

This must match the link number assigned on the node- 1 data

 

module screen.

 

 

Interface Chan

For TCP/IP, interface channel numbers are in the range 5000 –

 

64500.

 

The recommended values are: 5001 for CMS, 5002 for Intuity

 

AUDIX, and 5003 for DCS connections that are not gateways.

 

These three values should be reused for multiple instances of

 

these applications; for example, if there are two Intuity

 

AUDIX’s, use 5002 for both; or if there are four DEFINITY

 

ECS’s, use 5003 for all four. The combination of Link, Interface

 

Channel, and Mach ID must be unique.

 

The recommended values for gateway switches is 6001–6099.

 

The interface channel number must be unique for each gateway.

 

This number must match the Destination Port number on the

 

node-3 Processor Channel screen.

 

 

 

2 of 3

 

 

Administration for Network Connectivity

130

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 150
Image 150
Lucent Technologies Release 8.2 manual 130 CID