QSIG

 

B Private Networking

 

Internal Automatic Answer (IAA)

 

 

If the IAA feature is enabled, QSIG SS-CC calls are not answered automatically.

 

Manual Originating Line Service

 

 

A manual originating service cannot request QSIG SS-CC.

 

Multimedia Endpoints

 

 

You cannot activate QSIG-CC towards multimedia data endpoints.

 

Restriction Features

 

 

~ Class of restriction (COR): Any terminal that is Origination-restricted cannot

 

 

activate SS-CC. Any terminal that is Termination-restricted cannot have

 

 

SS-CC activated towards it.

 

 

~ Class of Service (COS): To invoke SS-CC, the ACB field on the Class of

 

 

Service screen of the calling terminal must be set to yes.

 

Ringback Queuing

 

 

Ringback Queueing and ACB share the same button to indicate that they are

 

 

active. If the user has only one ACB button, then both features cannot be active at

 

 

the same time.

 

Outgoing Trunk Queuing

 

 

Outgoing Trunk Queueing cannot be invoked after the calling party answers the

 

 

priority call back call and no trunks are available. The SS-CCBS and SS-CCNR

 

 

request cancels at both PBXs.

 

Termination Extension Group (TEG)

 

 

You cannot activate QSIG SS-CC towards a TEG extension, but QSIG-CC

 

 

requests can be activated towards a single member in the group.

 

Uniform Call Distribution and Direct Department Calling

 

 

You cannot activate QSIG SS-CC towards a uniform call distribution group or a

 

 

direct department calling group extension, but you can activate towards a single

 

 

member in the group.

 

Vector Directory Number (VDN)

 

 

You cannot activate SS-CC towards a VDN extension.

Message Waiting

AAR/ARS Partitioning

Indications

All QSIG MWI messages use Partition Group 1 for routing.

Alternate Facilities Restriction Levels QSIG MWI messages have unrestricted COR.

DCP and Mode Code links to AUDIX

QSIG MWI does not work with the DEFINITY AUDIX that emulates a DCP phone. A Prologix that communicates with AUDIX by using mode codes cannot be a QSIG message center switch complex.

Administration for Network Connectivity

 

 

555-233-504 — Issue 1 — April 2000

CID: 77730

383

Page 403
Image 403
Lucent Technologies Release 8.2 manual Message Waiting, Indications