Code

Enter the circuit pack code. If there is a physical circuit pack installed in the slot, the

 

entry must match that of the circuit pack. If there is equipment administered on a slot,

 

the equipment must be removed from the circuit pack before the circuit pack can be

 

changed or removed.

 

 

 

Valid entries

 

Usage

 

 

 

TN followed by a 3- or

 

 

 

4-digit number of a valid

 

 

 

DEFINITY circuit pack.

 

 

 

a valid ADXxxx number

 

 

 

a valid ASAIxx number

 

 

 

a valid DIGx number

 

 

 

LGATE

 

 

 

TN802

 

For the IP Interface assembly (TN802B/MAPD).

 

 

 

There must be at least two empty slots preceding the

 

 

 

slot administered as code TN802. The Code field for

 

 

 

these empty slots will automatically be populated

 

 

 

with DSMAPD, which must be changed to

 

 

 

MEDPRO for the MedPro mode of the IP

 

 

 

Interface/TN802B.

 

 

 

 

Sfx

Enter the circuit pack suffix, if applicable.

 

 

Valid entries

 

 

Usage

 

 

 

 

B to Z

 

 

 

 

blank

 

 

 

 

 

 

 

Mode

This is a display-only field that shows the circuit pack mode, if applicable.

 

Note:

 

 

 

 

Valid entries

 

 

Usage

 

 

 

 

Display-only field.

 

 

 

 

 

 

Name

This is a display-only field showing the alphanumeric name of the circuit pack (such

 

as Digital Line).

 

 

 

 

Note: Note: When the circuit pack physically inserted in the slot differs from

 

what has been administered on this screen, a "#" displays between the Sfx

 

and Name fields.

 

 

Valid entries

 

 

Usage

 

 

 

 

Display-only field.

 

 

 

 

 

 

 

 

 

 

 

 