Configuration 2: R7r (+CMS) <—ethernet—> R7csi

3 C-LAN Administration

 

 

 

 

 

Field

Conditions/Comments

 

 

 

 

 

Session - Local

The Local and Remote Session numbers can be any value

 

 

between 1 and 256 (si model) or 384 (r model), but they must

 

Session -

 

be consistent between endpoints. For each connection, the

 

Remote

 

Local Session number on this switch must equal the Remote

 

 

 

 

Session number on the remote switch and vice versa.

 

 

It is allowed, and sometimes convenient, to use the same

 

 

number for the Local and Remote Session numbers. It is

 

 

allowed, but not recommended, to use the same Session

 

 

numbers for two or more connections.

 

 

 

 

Mach ID

Destination switch ID. This is the Local Node Number on the

 

 

dial plan of the destination switch.

 

 

 

 

 

 

 

3 of 3

 

 

 

 

 

> Submit the screen

 

 

 

End

 

 

 

 

 

 

Intuity System Administration

Procedure Overview The following is a checklist of procedures that must be completed to administer a DEFINITY ECS with a TCP/IP connection to a Lucent Intuity system. The DEFINITY administration procedures are described in DEFINITY ECS Administrator’s Guide , 555-233-502 and in previous sections of this chapter. The Intuity system administration procedures are describe following the checklist.

For a complete description of the administration procedures for connecting an Intuity system to a DEFINTIY ECS, see Intuity Messaging Solutions — Using a LAN to Integrate with DEFINTIY ECS, 585-313-602 for Intuity R4.4 or 585-313-604 for Intuity R5.

DEFINITY ECS administration

The following procedures must be done on the host switch:

Administer the local node number in the dial plan.

Administer the Intuity system voice ports as stations, including Class of Restriction (COR) and Class of Service (COS).

If the switch is a csi model, assign the bus bridge.

Assign node names for the Intuity system and the switch.

Administer a hunt group, and add the Intuity system voice ports to that hunt group.

Add an ethernet data module.

Administer a processor channel for the link from the switch to the Intuity system.

Enable the link on the ethernet data module.

Set up a coverage path for access to the voice port hunt group.

 

 

Administration for Network Connectivity

92

CID: 77730

555-233-504 — Issue 1 — April 2000

Page 112