10. Storage

HBZ2610

10. Storage

BEFORE STORING THE BLOWER:

1.Drain a fuel tank and push the primer bulb until it becomes empty of fuel.

2.Remove the spark plug and drop a spoonful of 2-cycle oil into the cylider. Crank the engine several time and install the spark plug.

3.Store unit in a dry, dust free place, out of the reach of children.

11. Disposal

When disposing your machine, fuel or oil for the machine, be sure to allow your local regulations.

12.Optional vacuum kit usage

See the operating instructions included with the vacuum kit.

13.Troubleshooting guide

Case 1. Starting failure

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel

drain it and with correct fuel

fuel filter

fuel filter is clogged

clean

carburetor adjustment screw

out of normal range

adjust to normal range

sparking (no spark)

spark plug is fouled/wet

clean/dry

 

plug gap is incorrect

correct (GAP: 0.6 – 0.7 mm)

spark plug

disconnected

retighten

 

 

 

 

 

Case 2. Engine starts but does not keep running/Hard re-starting.

CHECK

 

PROBABLE CAUSES

 

ACTION

fuel tank

incorrect fuel or staled fuel

drain it and with correct fuel

carburetor adjustment screw

out of normal range

adjust to normal range

muffler,cylinder (exhaust port)

carbon is built-up

wipe away

air cleaner

clogged with dust

wash

cylinder fin, fan cover

clogged with dust

clean