10mm
Live
Earth
Neutral
Diagram 10

5.A dual position cable clamp is provided. For top cable entry use retaining bar in horizontal position supplied. For bottom cable entry rotate retaining bar to the angled position.

6.WARNING: THIS APPLIANCE MUST BE EARTHED.

7.The earth

continuity 8mm

c)Power selection operates in both positions, giving a change in water temperature

d)Check again for leaks

e)That the holes in the spray plate are not blocked

f)That the motor turns off and water stops flowing in the 'STOP' position

conductor of

5mm

3. DEMONSTRATE OPERATION TO THE USER

the electrical

10mm

Please leave these instructions with the user

installation 33mm

MUST BE effectively connected

electrically to all exposed parts of the appliances and services in the room in which the water heater is to be installed in conformity with the current BS. 7671 (I.E.E. wiring regulations).

FINAL INSTALLATION PROCEDURE AND COMMISSIONING

WARNING : DO NOT SWITCH ON THE ELECTRICITY SUPPLY UNTIL THE FOLLOWING PROCEDURE HAS BEEN COMPLETED. FAILURE TO DO SO COULD CAUSE THE PUMP TO RUN DRY AND INVALIDATE THE GUARANTEE.

1.Fit the front cover back into position, ensuring that both the control knobs are correctly aligned with the flow valve and power selector. Secure with top and bottom screws.

2.Fit hose and prime the shower first without the handset to flush out any remaining debris. To prime the shower ensure that the electricity supply is switched off. Turn control knob 'B' fully anti-clockwise. Water should start to flow with motor switched off allowing all the air to be purged out of the shower unit.

It may be necessary to lower the hose below the level of the shower unit whilst priming.

Stop water flow by turning knob 'B' fully clockwise. Attach handset, switch on electrical supply and then operate the shower as on page 2 and check–

a)That the water gets to a satisfactory temperature

b)Water flow can be adjusted by knob 'B'

for future reference.

ADDITIONAL ACCESSORIES

 

Cat. No.

White 2 metre shower hose

83-593529

1 metre riser rail

83-593530

Water control tap

93-792452

Shower de-scaling powder

95-711015

Curtain and rail pack

83-792802

Curtain and rail pack with non

 

slip bath mat

83-792801

Spare parts/accessories can be supplied against any Visa or Access cards from Redring Sales 01733 456700.

INLET ASSEMBLY SHOWING FILTER POSITION

Diagram 11

9

Page 9
Image 9
Redring 570 installation instructions Earth Continuity 8mm, Installation 33mm