b)Water too Check power is on (indicated
COLD | by 'power on' light). |
| Decrease water flow by |
| adjusting the temperature |
| control (knob 'B') clockwise to |
| a higher number on the |
| temperature scale. |
| Switch power to '• high |
| power' setting. |
| Select inner or outer spray |
| patterns only . |
|
|
c) Pump | Water starvation. Stop pump |
| immediately by turning knob |
Professional Service
If the previous checks fail to restore the performance, you should seek professional help.
The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified serviceman.
Warning! Switch off the electricity at the isolating switch before removing the cover to make checks.
operates but |
|
no water is 'B' fully clockwise to the | |
delivered | '• Stop position'. Check the |
| cold water cistern is full. |
| Ensure water supply pipe is not |
| blocked or |
| shower unit (see |
| commissioning) with power to |
a)Water too
HOT
Water flow restricted by blockage in filter. Switch off water at service valve and fully isolate electricity supply. Remove shower from wall. Remove filter (see diagram 9) clean and replace.
shower switched off. |
d)Pump fails Thermal trip inside motor has
during | operated. Wait for motor to |
shower | cool down (approx 30 mins). |
|
|
e) Spray | Clean showerhead (see page |
b)Water too
COLD
Check circuit through thermal
Check circuit through microswitches on the pressure switch.
Check each element circuit. Check tightness of electrical connections.
pattern poor 4) and flush heater.
Select an outer/inner spray pattern.
f)Water takes Thermal
longer to after previous use ('overheat'
c)Pump fails to operate
If the 'power on' light is lit, possible motor failure. Replace motor.
If the 'power on' light remains off, check motor switch. Replace if necessary.
heat up light is on). Switch power to
'• high power' setting.
f)Water goes Thermal
using | |
shower | Check power is on (indicated |
| by 'power on' light). |
f)Broken parts Please contact our spares department on 01733 456700.
d)Pump operates but no water is delivered
Faulty motor switch (short circuit). Replace.
Incorrect alignment of motor switch camdrive. In off position, the alignment marks on the cam drive (see diagram 2) should be centred about motor switch actuator.
Water flow restricted by blockage in filter. Switch off water and remove shower from wall. Remove filter (see diagram 9), clean and replace.
5