b)Water too Check power is on (indicated

COLD

by 'power on' light).

 

Decrease water flow by

 

adjusting the temperature

 

control (knob 'B') clockwise to

 

a higher number on the

 

temperature scale.

 

Switch power to 'high

 

power' setting.

 

Select inner or outer spray

 

patterns only .

 

 

c) Pump

Water starvation. Stop pump

 

immediately by turning knob

Professional Service

If the previous checks fail to restore the performance, you should seek professional help.

The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have a problem in the guarantee period.

The following additional checklist is provided for the benefit of the qualified serviceman.

Warning! Switch off the electricity at the isolating switch before removing the cover to make checks.

operates but

 

no water is 'B' fully clockwise to the

delivered

'Stop position'. Check the

 

cold water cistern is full.

 

Ensure water supply pipe is not

 

blocked or air-locked. Re-prime

 

shower unit (see

 

commissioning) with power to

a)Water too

HOT

Water flow restricted by blockage in filter. Switch off water at service valve and fully isolate electricity supply. Remove shower from wall. Remove filter (see diagram 9) clean and replace.

shower switched off.

d)Pump fails Thermal trip inside motor has

during

operated. Wait for motor to

shower

cool down (approx 30 mins).

 

 

e) Spray

Clean showerhead (see page

b)Water too

COLD

Check circuit through thermal cut-out.

Check circuit through microswitches on the pressure switch.

Check each element circuit. Check tightness of electrical connections.

pattern poor 4) and flush heater.

Select an outer/inner spray pattern.

f)Water takes Thermal cut-out has operated

longer to after previous use ('overheat'

c)Pump fails to operate

If the 'power on' light is lit, possible motor failure. Replace motor.

If the 'power on' light remains off, check motor switch. Replace if necessary.

heat up light is on). Switch power to

'high power' setting.

f)Water goes Thermal cut-out has operated cold while ('overheat' light is on) Wait for

using

cut-out to reset.

shower

Check power is on (indicated

 

by 'power on' light).

f)Broken parts Please contact our spares department on 01733 456700.

d)Pump operates but no water is delivered

Faulty motor switch (short circuit). Replace.

Incorrect alignment of motor switch camdrive. In off position, the alignment marks on the cam drive (see diagram 2) should be centred about motor switch actuator.

Water flow restricted by blockage in filter. Switch off water and remove shower from wall. Remove filter (see diagram 9), clean and replace.

5

Page 5
Image 5
Redring 570 installation instructions By power on light, Professional Service, High power setting