OPERATION AND ADJUSTMENT

THE PRE-LUBRICATED WALKING BELT

Your treadmill features a walking belt coated with high- performance lubricant. IMPORTANT: Never apply sil- icone spray or other substances to the walking belt or the walking platform. Such substances will cause excessive wear.

HOW TO PLUG IN THE POWER CORD

DANGER: Improper connection of the equipment-grounding conductor in- creases the risk of electric shock. Check with a qualified electrician or serviceman if you are unsure whether the product is properly grounded. Do not modify the plug—if it will not fit the outlet, have a proper outlet in- stalled by a qualified electrician.

Your treadmill, like other electronic equipment, can be damaged by sudden voltage changes in your home’s power. To decrease the risk of damaging your treadmill, always use a surge suppressor with your treadmill (see drawing 1 at the right). To purchase a surge suppressor, see precaution 12 on page 3. Use only a single-outlet surge suppressor that is UL 1449 listed as a transient voltage surge sup- pressor (TVSS). The surge suppressor must have a UL suppressed voltage rating of 400 volts or less and a minimum surge dissipation of 450 joules. The surge suppressor must be electrically rated for 120 volts AC and 15 amps. There must be a moni- toring light on the surge suppressor to indicate whether it is functioning properly. Failure to use a properly functioning surge suppressor could dam- age the control system of the treadmill (see precau- tion 13 on page 3).

This product must be grounded. If it should malfunc- tion or break down, grounding provides a path of least resistance for electric current to reduce the risk of elec- tric shock. This product’s power cord has an equip- ment-grounding conductor and a grounding plug. Plug the power cord into a surge suppressor, and plug the surge suppressor into an appropriate outlet

that is properly installed and grounded in accor- dance with all local codes and ordinances. IMPORTANT: The treadmill is not compatible with GFCI-equipped outlets.

This product is for use on a nominal 120-volt circuit

(see drawing 1). A temporary adapter may be used to

connect the surge suppressor to a 2-pole receptacle if

a properly grounded outlet is not available (see draw-

ing 2).

 

 

 

1

Grounded Outlet Box

 

 

 

Surge Suppressor

 

 

 

Grounding Pin

 

Grounding Pin

2

Grounded Outlet

 

Grounding Plug

Grounded Outlet Box

 

Adapter

Surge Suppressor

 

Lug

Grounding Plug

 

Metal Screw

The temporary adapter should be used only until a properly grounded outlet (see drawing 1) can be in- stalled by a qualified electrician.

The green-colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. The adapter must be held in place by a metal screw.

Some 2-pole receptacle outlet box covers are not grounded. Contact a qualified electrician to deter- mine if the outlet box cover is grounded before using an adapter.

11

Page 11
Image 11
Reebok RT 8.0 manual Operation AND ADJUSTMENT, PRE-LUBRICATED Walking Belt, HOW to Plug in the Power Cord