PROBLEM: The displays of the console do not function properly
SOLUTION: a. Remove the key from the console and unplug the power cord. Carefully tip the treadmill down as shown in drawing a. Remove the Screws (39, 83) from the hood. Raise the Uprights (69) and carefully re- move the hood.
Locate the Reed Switch (10) and the Magnet (7) on the left side of the Pulley (8). Turn the Pulley until the Magnet is aligned with the Reed Switch. Make sure that the gap between the Magnet and the Reed Switch is about 1/8”. If necessary, loosen the 1/2” Screw (67) and move the Reed Switch slightly. Retighten the Screw.
a |
| |
| 39 | |
69 | 83 | |
| ||
| Top View | |
1/8” | 8 | |
67 | ||
| ||
10 | 7 |
PROBLEM: The chest pulse monitor does not function properly
SOLUTION: a. If the chest pulse monitor does not function properly, see CHEST PULSE MONITOR TROUBLE- SHOOTING on page 8.
b. If the chest pulse monitor still does not function properly, the battery should be changed. To replace the battery, locate the battery cover on the back of the sensor unit. Insert a coin into the slot in the cover and turn the cover counterclockwise to the “open” position. Remove the cover.
Remove the old battery from the sensor unit. Insert a new CR 2032 battery, making sure that the writing is on top. In addition, make sure that the rubber gasket is in place in the sensor unit. Replace the bat- tery cover and turn it to the closed position.
Battery Cover
Battery
Cover
Battery
Rubber
Gasket
25