| Known Problems 39  | 
LAN Network Manager  | If you have previously configured your LAN Network Manager to use the  | 
with NETBuilder II  | NETBuilder II system as a virtual ring, and you want to use it as a physical ring, you  | 
Systems  | must set your virtual ring number back to None.  | 
LLC2 Frames and PPP | LLC2 frames are not sent or received over PPP unless global bridging is enabled  | 
  | using the SETDefault   | 
  | LLC2 on the port using:  | 
  | SETDefault !<port>   | 
  | If bridging is enabled and you do not want bridging, either set the   | 
  | CONTrol parameter to NoForward, or disable bridging on individual ports by  | 
  | setting the following command:  | 
  | SETDefault   | 
Remote Access  | To increase network security, the default value for the NetAccess parameter in the  | 
Default Change | SYS Service is set to NoRemote. This means that by default, no remote connection  | 
  | attempts will be accepted by the bridge/router. If you are accustomed to or want  | 
  | to use remote access, you must specifically set the value of the NetAccess  | 
  | parameter to Remote.  | 
SuperStack II and | For SuperStack II and OfficeConnect NETBuilder bridge/routers, flash memory is  | 
OfficeConnect Boot Path | the only storage media, which is not designated with a drive letter. When entering  | 
  | the boot path, do not specify a drive letter. Specifying a drive letter causes the  | 
  | boot load to fail.  | 
V.25bis Modem Setup | If you are using a V.25bis modem with a NETBuilder boundary routing leaf node,  | 
  | and you configure the line type explicitly as dial rather than auto, be certain to also  | 
  | set the DialMode to V.25bis rather than use the default of DTR.  | 
Web Link  | When you set the DocumentPath parameter in the WebLink service to a local file,  | 
Documentation Path | drive C for example (“file:///c:”), the Web Link assumes that access to the  | 
  | NETBuilder bridge/router takes place only from the computer to which the file is  | 
  | local. If Web Link is used from any other computer, the browser looks on its local  | 
  | “C” drive for the help pages. If the computer is a UNIX machine and these files are  | 
  | not present as expected, unpredictable browser behavior will result.  | 
Zmodem Time Out | A Zmodem file transfer from a PC to a SuperStack II or OfficeConnect  | 
  | bridge/router can take a long time. To minimize the possibility that the PC  | 
  | Zmodem software will time out during the download, run the DEFRag command  | 
  | on the SuperStack II bridge/router before beginning the file transfer. The DEFRag  | 
  | command reclaims dirty space in flash memory. Dirty space is memory that has  | 
  | been written on and cannot be used again until it has been erased.  | 
  | 
  | 
Known Problems | This section describes known problems in software version 11.1. Topics are in  | 
  | alphabetical order.  | 
APPN   | If you set up APPN routing in an SNA Boundary Routing configuration from a  | 
and SNA Boundary  | NETBuilder II bridge/router to a leaf node bridge/router,   | 
Routing | the remote site PC and the NETBuilder II bridge/router are established before you  | 
  | can configure the Boundary Routing configuration on the NETBuilder II  | 
  | bridge/router. However, after you set the   | 
  | and enable the   | 
  |