Regency H35, H200, H15, HI300, H25, H300, HI200 manual wood stoves, wood inserts

Models: HI300 H35 H300 H200 H25 H15 HI200

1 16
Download 16 pages 57.28 Kb
Page 13
Image 13
wood stoves

wood stoves

D

E

F

J H

G

I

A

B

C

Dimensions

H200

H300

A

23-7/8"

27"

B

27-5/8"

29-3/4"

B (short legs)

22-5/8"

24-3/8"

C

22-1/8"

25-1/2"

D

25-1/8"

26"

E

21"

24"

F

16"

16-1/8"

G

7"

7-1/8"

H

28-3/4"

30-1/4"

H (short legs)

23-3/4"

24-3/4"

I

15"

15"

J*

25-7/8"

27-1/4"

J* (short legs)

21"

22-1/8"

* to center line if rear vented.

Specifications

H200

H300

EPA Certified

Yes

Yes

Optimum Efficiency

74%

74%

Emissions (grams/hr)

3.9

4.1

Maximum BTU*

38,800

45,500

Typical Sq. Ft. Heated

400-1,000

800-2,000

Maximum Log Size

16"

18"

Firebox Size

1.34 cu. ft.

1.71 cu. ft.

Flue size

6"

6"

Burn time (typical)*

up to 6 hrs

up to 8 hrs.

Shipping Weight

425 lb

500 lb

*Length of burn time and BTU range depend on type of wood, climate condi- tions and installation.

B

E

D

*

 

A

 

C

F

Cwood insertsManual background F

Minimum Clearance To Combustibles

A

B

C

D

E

F

H300

Residential Installation "C" Vent

17"

15"

13"

30"

15"

19"

 

Residential Close Clearance

15"

10"

9"

28"

10"

15"

 

Mobile Home Close Clearance

15"

10"

9"

28"

10"

15"

H200

Residential Installation "C" Vent

17"

15"

13"

29"

17-1/8"

19-7/8"

 

Residential Close Clearance

15"

10"

9"

27"

12-1/8"

15-7/8"

 

Mobile Home Close Clearance

15"

10"

9"

27"

12-1/8"

15-7/8"

Note: In Canada floor protection must extend 18" to the front and 8" to the sides and back. With side load door floor protection must extend 18" to the side. In US same as above except floor protection extends 6" to sides and back.

*Minimum clearance with side load door is 18" to side wall. Refer to dimension (B) for clearance without side load door.

wood inserts

C

A

B

D

E

Dimensions

HI200

HI300

HI300 oversize

A

27-1/4"

30"

34-5/8"

B

--

21-1/2"

21-1/2"

C

39-13/16"

42-1/2"

51-3/4"

D

38-5/16"

40"

48-1/8"

E

6-3/8"

11-3/8"

11-1/4"

F

15-1/16"

17-1/4"

17-1/4"

G

9-5/8"

11-1/8"

11-1/8"

G (offset adaptor)

14-1/8"

--

--

H

21-1/4"

23-1/4"

23-1/4"

Specifications

HI-200

HI-300

EPA Certified

Yes

Yes

Optimum Efficiency

73.8%

77%

Emissions (grams/hour)

3.0

3.8

Maximum BTU*

55,000

75,000

Typical Sq. Ft. Heated

600-1,000

1,000-2,000

Maximum Log Size

18"

18"

Firebox Size

1.4 cu.ft.

2.3 cu.ft.

Flue size

6"

6"

Burn time (typical)*

up to 8 hrs.

up to 8 hrs.

Shipping Weight

258 lb.

500 lb.

*Length of burn time and BTU range depend on type of wood, climate conditions and installation.

G

H

F

B

C

A

D

 

E

F

G

 

Minimum Fireplace Opening

HI200

HI300

Width (front)

23"

25"

Height

19-5/8"

21-1/2"

Depth (w/ standard flue adaptor)

13-3/4"

17-1/2"

(w/ offset flue adaptor)

16-1/2"

 

Masonry & Factory Built Fireplace Clearances

The minimum required clearances to combustible materials when installed into a masonry fireplace are:

 

Adjacent Side Wall

Mantel

Top Facing

Side Facing (to

Min. Hearth

Min. Hearth

Min Hearth Side

 

(to side)

(to top)

(to top)***

side)***

Extension*

Elevation*

Extension**

 

A

B

C

D

E

F

G

HI200

15"

20"

14"

7-3/8"

18"CA/16"US

1-1/2"

8"/6" US

HI300

11"

20"

12"

8"

18"CA/16"US

0.5"

8"

* Note: If the hearth extension is flush with the floor (item F) it must extend 19.5 in. in front of the body face (item E).

** Note: Hearth extension width (G) is measured from edge of fuel door to side of hearth.13

*** up to 1-1/2" thick

Page 13
Image 13
Regency H35, H200, H15, HI300, H25, H300, HI200 manual wood stoves, wood inserts