gas fireplaces

43-1/4"

 

 

 

 

 

 

 

 

29-1/2"

31-1/4"

 

 

 

 

 

 

 

 

 

 

 

 

 

 

32-1/4"

Specifications

 

P36

P36 Deep

Maximum BTU

Natural Gas

30,000

30,000

 

Propane

30,000

30,000

 

 

 

 

Turn Down to (BTU)

Natural Gas

15,500

15,500

 

Propane

15,000

15,000

 

 

 

 

EnerGuide Rating

Natural Gas

62.7%

64.62%

(Canada only)

Propane

62.7%

64.62%

 

 

 

 

Efficiency

Natural Gas

82%

82%

 

Propane

82%

82%

 

 

 

 

Corner Framing - Top View

F

E

Minimum Termination Center Line

 

Header

 

10" Dia. hole

1/2"

through wall for

Flex or DuraVent

Drywall

 

 

I

 

G H

 

F

Flush Framing - Front View

 

 

Minimum height

 

D

to combustible

C

material

B

 

 

 

 

A

 

Mantel Clearances - Side View

 

12" Mantel

Drywall

 

7-1/2" Mantel

 

 

3-1/2"

Top nailing strip

N

Mantel

 

 

 

 

O

Top standoffs

 

 

 

P

 

J

Top

 

louvers

 

to floor

 

 

 

Side view

Framing

 

P36

 

P36 Deep

A

 

36-1/4"

 

36-1/4"

B

 

36-1/4"

 

37-1/4"

C

 

12-3/4"

 

17"

D

 

46"

 

46-1/2"

E (corner)

 

60"

 

68"

F (corner)

 

42-7/16"

 

48"

 

 

Minimum Termination Center Line

 

 

 

P36

P36 Deep

F

 

12-3/4"

 

17-1/8"

G

 

32-1/2"

 

32-1/2"

H

 

36"

 

37"

I

 

40-1/2"

 

40-1/2"

 

 

 

 

Mantel Clearances

 

 

 

 

 

P36

P36 Deep

J

 

30-1/2"

 

30-1/2"

N

 

14"

 

14"

O

 

10"

 

10"

P

 

7"

 

7"

gas fireplace inserts

40-3/4" 1/4"-26

Specifications

 

U31

U32

Maximum BTU

Natural Gas

30,000

30,000

 

Propane

27,500

30,000

Turn Down to (BTU)

Natural Gas

14,500

15,300

 

Propane

13,700

15,000

EnerGuide Rating

Natural Gas

52.9%

57.17%

(Canada only)

Propane

48.07%

57.17%

Efficiency

Natural Gas

76%

76%

 

Propane

77%

77%

 

Minimum Fireplace Opening

 

 

U31

U32

Width

 

26-1/2"

26-1/2"

Height

 

21"

22"

Depth

 

15"

14"

27-7/8"

* 4" hearth trim available for taller fireplace openings.

 

B

D

F

C

H

 

AI

G

Clearances To Combustibles

U31 / U32

A

Side Wall

10"

B

Ceiling

47-1/2"

C

Mantel

17"

D

Mantel depth

12"

E

Alcove Width

48"

F

Max. Alcove Depth

36"

 

 

Non-Combustible Hearth Requirements

 

G

Hearth Thickness

0"

H

Hearth Depth

16"

I

Hearth Width

40"

NOTE: All product specifications are subject to change without notice. Before installing, refer to the relevant product manual for full and up to date information.

Color and tone variations are a natural result of the enameling process. Actual colors may not appear exactly as shown.

U31: Tested to the following standards: GAS FIRED VENTED ROOM HEATER

TESTED TO: ANSI Z21.88a-1998/CSA 2.33a-M98, CAN 1-2.1-M86, CAN/CGA 2.17-M91. Certified for Canada and the US.

U31 is bedroom and alcove approved.

U32: Tested to the following standards: GAS FIRED VENTED ROOM HEATER

TESTED TO: ANSI Z21.88-1998/CSA 2.33-M98, CAN /CGA 2.17-M91. Certified for Canada and the US.

U32 is bedroom, alcove and mobile home approved.

All products tested to the following standards: GRAVITY DIRECT VENT WALL FURNACE TESTED AND APPROVED FOR U.S.A. AND CANADA TO:

E

CAN/CGA-2.17-M91, ANSI Z21.88b-1999/CSA 2.33b-M99.

15

Page 15
Image 15