INSTALLATION
6) Remove the burner orifice with a 1/2" wrench. | 9) |
Use another wrench to hold onto the elbow |
|
behind the orifice. Replace the NG burner | 10) Undo the center wire clip on the side of the |
orifice with LP orifice #49. | firebox. |
Burner Orifi ce |
|
7)Pull off the pilot cap to expose the pilot orifice.
11) Unplug the wire harness that connects the modulating coil to the receiver.
8)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifice.
12)Remove NG modulating regulator by undoing 3 screws and replace with LP modulating regulator.
13)Install the enclosed identification label to the valve body where it can be easily seen.
14)Attach the LP conversion decal near or on top of the serial no. decal.
15)Replace yellow "Natural Gas" label with red "Propane" label.
16)Adjust the burner aeration setting to the LP setting (1/2") and
17)
18)
19)
20)Continue with completing unit installation.
NOTE: Once the unit has been installed;
a)Turn on the gas supply and check for gas leaks.
b)Check the inlet and outlet pressures.
c)Check operation of flame control using the remote control.
INSTALLATION
d)Check for proper flame appearance.
Installer Notice:
This instructions must be left with the appliance.
Regency® | 29 |