Regency L900-1 Installation, Installer Notice, This instructions must be left with the appliance

Models: L900-1

1 48
Download 48 pages 532 b
Page 29
Image 29
Burner Orifi ce

INSTALLATION

6) Remove the burner orifice with a 1/2" wrench.

9) Re-install the pilot cap.

Use another wrench to hold onto the elbow

 

behind the orifice. Replace the NG burner

10) Undo the center wire clip on the side of the

orifice with LP orifice #49.

firebox.

Burner Orifi ce

 

7)Pull off the pilot cap to expose the pilot orifice.

11) Unplug the wire harness that connects the modulating coil to the receiver.

8)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifice.

12)Remove NG modulating regulator by undoing 3 screws and replace with LP modulating regulator.

13)Install the enclosed identification label to the valve body where it can be easily seen.

14)Attach the LP conversion decal near or on top of the serial no. decal.

15)Replace yellow "Natural Gas" label with red "Propane" label.

16)Adjust the burner aeration setting to the LP setting (1/2") and re-install the burner tube.

17)Re-install the grate.

18)Re-install the glass door.

19)Re-install the front cover plate

20)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a)Turn on the gas supply and check for gas leaks.

b)Check the inlet and outlet pressures.

c)Check operation of flame control using the remote control.

INSTALLATION

d)Check for proper flame appearance.

Installer Notice:

This instructions must be left with the appliance.

Regency® L900-1 Direct Vent Gas Fireplace

29

Page 29
Image 29
Regency L900-1 Installation, Installer Notice, This instructions must be left with the appliance, Burner Orifi ce