Specifications - Wood Stoves
FRONT WITH | TOP | FRONT WITH LEGS | |
PEDESTAL |
| ||
|
| ||
B |
| B | |
|
| ||
| D | C | |
A | E | ||
|
Minimum Clearance to Combustible Materials
Please read the section below carefully as clearances depend on whether the optional airmate convector or the rear heat deflector is installed on the stove. Measurements “From Unit” are from the top plate of the stove to a side wall or to a corner, and from the rear heat shield to a back wall.
Dimensions |
| A** | B |
|
| C*** |
| D |
| E** | |
Small F1100 |
|
| 24" |
| 20" |
| 6" |
| |||
Medium F2400 |
|
| 24" |
|
| 6" |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
Large F3100 |
|
| 28" |
|
| 6" |
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
Medium S2400 |
|
| 24" |
|
| 6" |
| ||||
**Measured to top of flue collar for height |
|
|
|
|
|
|
|
| |||
***Including Ash Lip |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| Flat Top |
|
|
|
|
| Step Top | |
Classic Stoves |
| F1100 |
| F2400 |
| F3100 |
|
| S2400 | ||
| Small Stove |
| Medium Stove |
| Large Stove |
| Medium Stove | ||||
Maximum BTU* | 55,000 |
| 75,000 |
|
| 80,000 |
| 75,000 | |||
|
|
|
|
|
|
|
|
| |||
Typical Sq. Ft. Heated |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
| |||
Optimum Efficiency | 73.8% |
| 77% |
|
| 71% |
| 77% | |||
|
|
|
|
|
|
|
|
| |||
Maximum Log Size | 18" |
| 18" |
|
| 21" |
| 18" | |||
|
|
|
|
|
|
|
| ||||
Burn Time (Typical)* | up to 8 hrs |
| up to 8 hrs |
| up to 10 hrs |
| up to 8 hrs | ||||
|
|
|
|
|
|
|
|
|
| ||
Emissions (grams/hr) |
| 3.0g |
| 3.4g |
| 4.2g |
|
| 3.4g | ||
|
|
|
|
|
|
|
|
| |||
Firebox Size | 1.4 cu. ft. |
| 2.3 cu. ft. |
| 2.9 cu. ft. |
|
| 2.3 cu. ft. | |||
|
|
|
|
|
|
|
|
| |||
Flue Size | 6" |
| 6" |
|
| 6" |
| 6" | |||
|
|
|
|
|
|
|
|
|
|
|
|
* Length of burn time and BTU range depend on type of wood, climate conditions and installation.
B | E |
|
|
|
6" |
|
|
| 6" |
A |
|
|
| |
|
|
|
| |
|
|
|
| F |
D |
| 16" |
| C |
|
|
| ||
|
|
|
| |
6" | 16" |
|
| 6" |
|
|
| ||
|
|
| F | C |
|
|
|
|
Residential Installation “C” Vent (Single Wall) |
| FROM UNIT | FROM CORNER | FROM FLUE | ||||
|
| A |
| B | C | D | E | F |
Small F1100 | with AirMate | 13" |
| 11" | 8" | 25" | 17.5" | 20" |
| with Rear Deflector | 15" |
| 10.5" | 11" | 27" | 17" | 23" |
Medium S2400 | with Step Top | 16" |
| 11" | 6" | 28" | 17.5" | 17.5" |
Medium F2400 | with AirMate | 16" |
| 11" | 6" | 28" | 17.5" | 17.5" |
| with Rear Deflector | 18" |
| 12" | 6.5" | 30" | 18.5" | 19.5" |
Large F3100 | with AirMate | 18" |
| 12" | 8.5" | 32" | 18.5" | 22" |
| with Rear Deflector | 20" |
| 14" | 10.5" | 34" | 20.5" | 24" |
These clearances are certified clearances for the stove, however, the clearance to the combustibles and the single wall stove pipe must also be maintained. You can reduce the stove pipe clearance with a stove pipe heat shield.
Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from the stove collar to the ceiling level.
Residential Close Clearance |
| FROM UNIT | FROM CORNER | FROM FLUE | ||||
(To be installed with required pipe components) | A |
| B | C | D | E | F | |
Small F1100 | with AirMate | 9" |
| 5" | 3" | 21" | 11.5" | 15" |
| with Rear Deflector | 13.5" |
| 5" | 5" | 25.5" | 11.5" | 17" |
Medium S2400 | with Step Top | 15" |
| 5.5" | 4" | 27" | 12" | 15.5" |
Medium F2400 | with AirMate | 15" |
| 5.5" | 4" | 27" | 12" | 15.5 |
| with Rear Deflector | 15" |
| 6.5" | 6" | 27" | 13" | 17.5" |
Large F3100 | with AirMate | 16" |
| 9.5" | 8.5" | 30" | 16" | 22" |
| with Rear Deflector | 20" |
| 12" | 8.5" | 34" | 18.5" | 22" |
H | J |
G |
|
I |
|
| K |
20
Minimum Alcove Clearance to Combustible Materials
The Regency® Freestanding models have been alcove approved and must be installed with a listed double wall connector to the ceiling level.
Note: Minimum alcove ceiling height - 84 in. / Maximum depth of alcove - 36 in.
Minimum Alcove Clearance |
| FROM UNIT |
| FROM FLUE | MIN. WIDTH | ||||
|
| G |
| H |
| I |
| J | K |
Small F1100 | with AirMate | 11" |
| 7" |
| 23" |
| 13.5" | 46" |
| with Rear Deflector | 13" |
| 5" |
| 25" |
| 11.5" | 50" |
Medium S2400 | with Step Top | 15" |
| 5.5" |
| 27" |
| 12" | 54" |
Medium F2400 | with AirMate | 15" |
| 5.5" |
| 27" |
| 12" | 54" |
| with Rear Deflector | 15" |
| 6.5" |
| 27" |
| 13" | 54" |
Large F3100 | with AirMate | 16" |
| 9.5" |
| 30" |
| 16" | 60" |
| with Rear Deflector |
|
|
| not | approved for Alcove |
|
|
Mobile Home Close Clearance (To be installed with required pipe components)
“C” Vent single wall pipe is not approved for mobile home installations. (Refer to mobile home instruc- tions)
Mobile Home Close Clearance |
| FROM UNIT | FROM CORNER | FROM FLUE | ||||
(To be installed with required pipe components) | A |
| B | C | D | E | F | |
Small F1100 | with AirMate | 11" |
| 6" | 6" | 23" | 12.5" | 18" |
| with Rear Deflector | 13" |
| 5" | 9" | 25" | 11.5" | 21" |
Medium S2400 | with Step Top | 15" |
| 5.5" | 4" | 27" | 12" | 15.5" |
Medium F2400 | with AirMate | 15" |
| 5.5" | 4" | 27" | 12" | 15.5" |
| with Rear Deflector | 15" |
| 6.5" | 6" | 27" | 13" | 17.5" |
Large F3100 | with AirMate | 18" |
| 9.5" | 10" | 32" | 16" | 23.5" |
| with Rear Deflector | 20" |
| 12" | 10" | 34" | 18.5" | 23.5" |