Regency F2400, S2400 manual Classic Wood Stove Floor Protection, Corner Installations

Models: S2400 F2400

1 24
Download 24 pages 7.74 Kb
Page 21
Image 21
CLASSIC WOOD STOVE FLOOR PROTECTION

CLASSIC WOOD STOVE FLOOR PROTECTION

B

A

USA FLOOR PROTECTION

 

Residential “C” Vent

Residential Close Clearance

Mobile Home

 

Alcove

 

Close Clearance

 

Flush Wall Hearth Requirements

 

 

 

 

 

 

 

A

B

A

B

A

B

A

 

B

 

 

 

Small F1100

with AirMate

36"

38"

36"

37"

36"

38"

36"

 

38"

 

with Rear Deflector

36"

38"

36"

37"

36"

37"

36"

 

37"

Medium S2400

with Step Top

36"

46"

36"

45"

36"

45"

36"

 

45"

Medium F2400

with AirMate

36"

46"

36"

45"

36"

45"

36"

 

45"

 

with Rear Deflector

36"

46"

36"

45"

36"

45"

36"

 

45"

Large F3100

with AirMate

40"

43"

40"

43"

40"

43"

40"

 

43"

 

with Rear Deflector

40"

43"

40"

43"

40"

43"

 

Not approved

 

 

 

 

 

 

 

 

 

for alcove

 

 

 

 

 

 

 

 

 

 

CANADA FLOOR PROTECTION

Residential “C” Vent

Residential Close Clearance

Mobile Home

 

Alcove

Close Clearance

 

Flush Wall Hearth Requirements

 

 

 

 

 

 

 

A

B

A

B

A

B

A

 

B

 

 

 

Small F1100

with AirMate

40"

42"

40"

41"

40"

42"

40"

 

42"

 

with Rear Deflector

40"

42"

40"

41"

40"

41"

40"

 

41"

Medium S2400

with Step Top

40"

50"

40"

49"

40"

49"

40"

 

49"

Medium F2400

with AirMate

40"

50"

40"

49"

40"

49"

40"

 

49"

 

with Rear Deflector

40"

50"

40"

49"

40"

49"

40"

 

49"

Large F3100

with AirMate

44"

47"

44"

47"

44"

47"

44"

 

47"

 

with Rear Deflector

44"

47"

44"

47"

44"

44"

Not approved for alcove

 

 

 

 

 

 

 

 

 

 

 

B

C

D

A

USA FLOOR PROTECTION

 

 

Residential “C” Vent

 

Residential Close Clearance

 

Mobile Home

 

 

 

 

 

Close Clearance

 

Corner Hearth Requirements

 

 

 

 

 

 

 

 

 

 

 

A

B

C

 

D

A

B

C

D

A

B

C

D

 

 

 

Small F1100

with AirMate

36"

52.75"

45.75"

 

21.25"

36"

47.75"

40.75"

16.25"

36"

50.75"

43.75"

19.25"

 

with Rear Deflector

36"

57.25"

49.25"

 

25"

36"

49.75"

42.75"

18.25"

36"

58.25"

50.25"

26"

Medium S2400

with Step Top

36"

57.5"

53.5"

 

26.5"

36"

55"

52.5"

24.75"

36"

55"

52.25"

24.75"

Medium F2400

with AirMate

36"

57.5"

53.5"

 

26.5"

36"

55"

52.5"

24.75"

36"

55"

52.25"

24.75"

 

with Rear Deflector

36"

58"

54"

 

27"

36"

57.5"

53.5"

27"

36"

57.5"

53.5"

27"

Large F3100

with AirMate

40"

60.75"

53"

 

24.25"

40"

60.75"

53"

24.25"

40"

60.25"

54.5"

24.25"

 

with Rear Deflector

40"

63.5"

53.5"

 

26.25"

40"

60.75"

53"

24.25"

40"

63"

54.5"

24.25"

Corner Installations

If the rear clearance to combustibles is less than 6", for corner installations the corners may be angled to take advantage of the closer clearances.

6"

6"

CANADA FLOOR PROTECTION

 

Residential “C” Vent

 

Residential Close Clearance

 

Mobile Home

 

 

 

 

Close Clearance

 

Corner Hearth Requirements

 

 

 

 

 

 

 

 

 

 

 

A

B

C

 

D

A

B

C

D

A

B

C

D

 

 

 

Small F1100

with AirMate

40"

54.75"

47.75"

 

19.25"

40"

49.75"

42.75"

14.25"

40"

52.75"

45.75"

17.25"

 

with Rear Deflector

40"

59.25"

51.25"

 

23"

40"

51.75"

44.75"

16.25"

40"

60.25"

52.25"

24"

Medium S2400

with Step Top

40"

59.5"

55.5"

 

28.5"

40"

57"

54.5"

26.75"

40"

57"

54.25"

26.75"

Medium F2400

with AirMate

40"

59.5"

55.5"

 

28.5"

40"

57"

54.5"

26.75"

40"

57"

54.25"

26.75"

 

with Rear Deflector

40"

60"

56"

 

29"

40"

59.5"

55.5"

29"

40"

59.5"

55.5"

29"

Large F3100

with AirMate

44"

62.75"

55"

 

22.25"

44"

62.75"

55"

22.25"

44"

62.25"

56.5"

22.25"

 

with Rear Deflector

44"

65.5"

55.5"

 

24.25"

44"

62.75"

55"

22.25"

44"

65"

56.5"

22.25"

Floor Protection

A combustible floor must be protected by non-combustible material (like tile, concrete board, or certified to UL-1618 or as defined by local codes) extending beneath the heater and a minimum of 6" (USA) or 8" (250mm) (Canada) from each side and minimum 16" (USA) or 18" (450mm) (Canada) from the front face of stove and minimum 6" (USA) or 8" (250mm) (Canada) or the rear clearance to combustibles, whichever is smaller, from the rear of the stove.

When installed with horizontal venting, non-combustible floor protection must be installed beneath the flue pipe and extend 2" (51mm) beyond each side.

21

Page 21
Image 21
Regency F2400, S2400 manual Classic Wood Stove Floor Protection, Corner Installations