Gas Inserts
U32 Regency Gas Insert
U32 Regency Gas Insert
Model |
| |||
Fuel Type |
| Natural Gas | Propane | |
|
|
|
| |
Minimum Supply Pressure | 5” W.C. (1.25 kPa) | 12” W.C. (2.99 kPa) | ||
|
|
|
| |
Manifold Pressure - High | 3.8” W.C. (0.95 kPa) | 11” W.C. (2.74 kPa) | ||
|
|
|
| |
Manifold Pressure - Low | 1.1” W.C. (0.27 kPa) | 2.9” W.C. (0.72 kPa) | ||
|
|
|
|
|
Orifice Size |
|
| #37 DMS | #52 DMS |
|
|
|
|
|
Minimum Input |
| 15,300 BTU/h | 15,000 BTU/h | |
Altitude |
|
| (4.48 kW) | (4.40 kW) |
|
|
|
|
|
Maximum Input |
| 30,000 BTU/h | 30,000 BTU/h | |
Altitude |
|
| (8.79 kW) | (8.79 kW) |
|
|
|
|
|
Vent Sizing |
| 3” | 3” | |
|
|
|
| |
|
|
| ||
Approved Venting Systems |
| |||
Flex Vent Systems: |
| FPI AstroCap™ Flex Vent | ||
|
|
|
|
|
| A |
B |
|
| C |
| G |
F | I |
| |
H D |
|
E |
|
Dimension | Description | U32 |
|
|
|
A | Faceplate Width | |
B | Faceplate Height | |
C | Unit Width | 28” (711mm) |
D | Unit Height | 20” (508mm) |
E | Unit Depth | |
F | Faceplate to Vent Centerline | |
G | Faceplate Depth | |
H | Height to Vent Collar | |
I | Optional or Standard Front Depth | |
|
|
|
Minimum Fireplace Dimensions
The minimum fireplace dimensions for the FPI gas fireplace insert are shown in the following diagrams:
| M |
J | L |
K |
N |
Dimension | Description | Contour | Molded | |
Faceplate | Faceplate | |||
|
| |||
J | Height | 22” (559mm) | 22” (559mm) | |
K | Width | 29” (737mm) | ||
L | Depth | 14” (356mm) | 15” (381mm) | |
M | Max. Lintel Bar Depth | 9” (229mm) | 10” (254mm) | |
N | Rear Width |
Gas Inserts
August 2008 Product Specifications Book | 125 |