Gas Inserts
U32 Regency Gas Insert
Clearances
Unless otherwise stated the clearances listed below are Minimum distances to combustible materials. Please Note: A major cause of chimney related fires is due to a failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions.
Clearances to Combustibles
Dimension | Description | U32 | |
A | From Unit to Sides | 10” (254mm) | |
B | From Unit to Ceiling | 47.5” (1207mm) | |
C | From Unit to Mantel | see diagram 2 & 3 | |
D | From Standard Surround to Sides | 4” (102mm) | |
E | From Standard Surround to Ceiling | 41.5” (1054mm) | |
also see diagram 2 & 3 | |||
|
| ||
G | Maximum Mantel Depth | 12” (305mm) | |
see diagram 2 | |||
|
| ||
H | Minimum Alcove Width | 48” (1219mm) | |
I | Maximum Alcove Depth | 36” (914mm) |
*No Hearth Required
Gas Inserts
Combustible Mantels
Because of the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of the louvers are shown in the diagram below. Mantel may be installed anywhere in the shaded area or higher.
C
A
D
E
G
H
B
I
Note: A
Note: Ensure the paint that is used on the mantel and the facing is “heat resistant” or the paint may discolour.
| 12" Max. |
Mantle | G |
| |
| C |
Faceplate | Combustible |
| |
| Flooring |
| Flush |
| with |
| Floor |
126 | August 2008 Product Specifications Book |