Every six months, lubricate the trimmer teeth by applying a drop of light machine oil one-third and two-thirds of the way along the blade. Using your finger tip, spread the oil along the teeth, and run the trimmer for a few seconds.

Replacing Foils and Cutters

Because they are subject to daily use, the cutters and foils of your Remington® MicroScreen® 2 Shaver will wear and eventually require replacement to maintain a close, comfortable shave. Depending on your shaving technique and habits, the foils will usually last six months; the cutters, one year. Model DA-757 has a foil replacement indicator.

The foil icon on the LCD display will flash when the foil is due for replacement. Some signs that your foils and cutters need replacing are:

Irritation. As foils get worn, you may notice your skin feeling sensitive after a shave, particularly when you apply aftershave.

Pulling. As cutters wear, your shave may not feel as close, and you may feel your shaver is pulling at your whiskers.

Wear-through. You may notice that the cutters have worn through the foil.

To order replacement foils and cutters, call 1-800-736-4648.

To prevent inadvertent damage to the Foils and Cutter Assembly, do not attempt to remove them unless you are replacing them. To remove the old foil and cutters follow the instructions that come with the foil and cutter replacement package. It's always a good idea to replace the foils when you replace the Cutter Assembly.

To Replace a Cutter Assembly That is Removed Unintentionally:

Hold the assembly in the middle of the "T."

Gently place the forked legs into the open- ing at the top of the oscillator tips.

Do not push downward on the ends of the cutters, as you may bend the cutter, reducing its ability to operate smoothly.

Do not remove cutters from the plastic pieces to which they are attached, as you may damage the assembly.

Removing the Headguard

Before operating your MicroScreen® 2 Shaver, remove the Headguard, which protects the Foils and Cutter Assembly. It is important to remove the Headguard correctly to avoid damaging the clips that hold

it firmly to the shaver.

Press lightly on the top of the Headguard.

Lift the lower rear edge.

Pull the Headguard away from the shaver.

Operation

Use of a shaver at voltages other than the ones specified below will damage it and void the warranty. Model DA-57,DA-107 - Corded Shavers 120 Volts A.C.

Model DA-307, DA-325 - Rechargeable Shaver

World-wide A.C.voltage:105-130 Volts A.C.

at 60 Hz,and 105-240 Volts,A.C. at 50 Hz.

Model DA-407 - Cord/Cordless Shaver World-wide A.C. voltage:100-240 Volts A.C.,50-60 Hz.

Model DA-757 - Cord/Cordless Shaver With LCD Display

World-wide A.C.voltage:100-240 Volts A.C.,50-60 Hz.

Charging

Charge your shaver 24 hours before initial use. Make sure the ON/OFF button is set to OFF (with “O” visible). Connect the cord to the shaver and then to the electric outlet.

Model DA-307, DA-325,and DA-407 The Green indicator light will glow indicating that the shaver is charging.

The shaver will be completely recharged in 14-16 hours. The red indicator light in the DA-325 model will glow when the shaver needs to be recharged.

Model DA-757This shaver has an LCD display. The bars on the display give the % of battery power left in your shaver. The plug icon will flash when your shaver needs to be recharged. There is also a foil replacement indica- tor. The foil icon on the display will flash when the foil is due for replacement. The one hour quick charge feature in this model gives up to 60 minutes of cordless shaving time. A 5 minute quick charge gives enough shaving time for one shave

To Shave

Model DA-57,andDA-107Connect cord to shaver and then to electric outlet.Slide the ON/OFF button upward to turn ON.

Model DA-307 and DA-325With the shaver unplugged,press in on the Switch Lock and slide the ON/OFF button upward to turn ON.Note that this shaver is designed only to operate from its batteries; it must be charged before using.

Model DA-407,andDA-757These shavers can be powered from either the cord or the batter y. To shave using the batter y, make sure that the shaver has been charged. To shave using the cord,connect cord to shaver and then to electric outlet.Press in on the Switch Lock and slide the ON/OFF button upward to turn ON.

Trouble Shooting

If your DA-407, 757 shaver battery is completely discharged or the shaver has not been used for an extended period of time, the shaver may not start when oper- ated using the cord. If this condition occurs, charge the shaver for approximately five minutes before shaving.

Your DA-407, 757 cord/cordless shaver should not be used strictly as a cord- operated shaver, as continued cord only use will result in reduction of battery life.

In order to preserve the life of the batteries,they should be fully discharged every six months and then fully charged for 24 hours.

Battery Removal

(Cord/Cordless and Cordless
Rechargeable Models Only)

When your rechargeable shaver reaches the end of its useful life, the

batteries must be removed from the shaver and be recycled or disposed of properly in accordance with your local and state requirements.

The following procedure should be followed for battery removal:

To avoid a possible electrical shock hazard,unplug cord from electrical outlet and shaver.

Remove the head assembly by pushing in on the head assembly release buttons.

Remove the two screws on the upper back side of the shaver.

Pull or pry the shaver halves apart.

Pull out the motor and frame assembl y.

Pull or pry the batteries outward from the shaver’s circuit board.

Pull and twist the batteries to break the wire connections.

CAUTION:Do not put in fire or mutilate your batteries when disposing as they may burst or release toxic materials.Do not short circuit as it may cause burns.Dispose of properly in accordance with your local and state requirements.

CAUTION: THESE NICKEL-CADMIUM BATTERIES MUST BE RECYCLED OR DISPOSED IN ACCORDANCE WITH STATE AND LOCAL REGULATIONS. Do not burn or mutilate, as they

may burst or release toxic materials. Do not short-circuit, as it may cause burns.