2.6.4 LED Display When the Emulator Starts Up Normally
Figure 2.4 shows upper panel LED lighting status when the emulator started up properly. Check it when starting up the
emulator system.
POWER
CLOCK
RUN
RESET
WARNING
TARGETSTATUS
SYSTEMSTATUS
POWER
SAFE
ERROR
: ON
: OFF
: Flashing
- If this LED does not light, check the voltage of the user system.
- Check power is supplied to all the power terminals.
- When the user system is not connected, this LED does not light.
Figure 2.4 LED display when the power turned on PC7501
IMPORTANT
Note on CLOCK LED:
If CLOCK LED does not turn on, check the following:
(1) Immediately after starting PC7501 (before starting the emulator debugger)
Check if the oscillation circuit within the PC7501 emulator main unit oscillates normally.
(2) After starting the emulator debugger (after setting the Init dialog box)