Operational Specifications 
3.3.1 SH7125 Power Supply Select Jumper (JP1) 
Rev.1.0 July 21, 2006  3-13
REJ10J0952-0100     
3 
3.3.1 SH7125 Power Supply Select Jumper (JP1) The JP1 allows the sources for the SH7125 power supply voltages to be selected. 
Figure 3.3.2 shows the SH7125 power supply voltage select jumper (JP1) assignment. 
Table 3.3.1 lists jumper setting for selecting SH7125 power supply voltage (JP1). 
Top view of the 
component side
Board 
edge
Board 
edge
13
JP1 PWRSEL
Figure 3.3.2 SH7125 Power Supply Voltage Select Jumper (JP1) Assignment 
Table 3.3.1 Jumper Setting for Selecting SH7125 Power Supply Voltage (JP1) 
Jumper Setting  Function 
1 - 2  5V fixed power supply voltage 
JP1 
 PWRSEL  2 - 3  External power supply voltage (supplied from J4) 
   : Initial Setting 
Note : Do not change jumper settings while the operation of M3A-HS25. Ensure to turn off the power for the 
M3A-HS25 before changing jumper settings.