( 12 / 18 )
4.5 Precautions When Opening and Closing IC SocketWhen opening and closing the IC socket, hold the adapter horizontally as shown in Figure 4.4.
Otherwise the inside of the IC socket may become damaged and cause an electrical insulation failure.
Figure 4.4 Holding the adapter in a horizontal position
4.6 Precautions When Handling AdapterDo not directly touch the connector in the IC socket and the pins on the PROM programmer connector
because dirt may cause an electrical insulation failure.
When not using this product, attach the connector pins of this product to the conductive sponge as
it was shipped from the factory.
4.7 Setting Programming AreaWhen writing and erasing programs, be sure to set the programming area. And also, specify its device
of the PROM programmer.
Table 4.1 Programming area
Side view
MCU Internal flash
memory
area of MCU
M5M28F101
ROM size Programming areaDevice
PROM programmer
M38B79FFFP 100016 - FFFF160100016 - 0FFFF1660KB