ResMed VPAP Adapt SV manual Portable and mobile RF communications

Models: VPAP Adapt SV

1 42
Download 42 pages 12.08 Kb
Page 38
Image 38

Guidance and manufacturer’s declaration – electromagnetic immunity (continued)

The VPAP Adapt SV is intended for use in the electromagnetic environment specified below. The customer or the user of the VPAP Adapt SV should assure that it is used in such an environment.

Immunity

IEC60601-1-2

Complianc

Electromagnetic environment –

test

test level

e level

guidance

 

 

 

 

 

 

 

Portable and mobile RF communications

 

 

 

equipment should be used no closer to any

 

 

 

part of the VPAP Adapt SV, including cables,

 

 

 

than the recommended separation distance

 

 

 

calculated from the equation applicable to the

 

 

 

frequency of the transmitter.

 

 

 

Recommended separation distance

Conducted RF

3 Vrms

3 Vrms

d = 1.17 P

IEC 61000-4-6

150 kHz to 80 MHz

 

 

Radiated RF

10 V/m

10 V/m

d = 0.35 P 80 MHz to 800 MHz

IEC 61000-4-3

80 MHz to 2.5 GHz

 

 

 

 

 

d = 0.70 P 800 MHz to 2.5 GHz

 

 

 

where P is the maximum output power rating

 

 

 

of the transmitter in watts (W) according to the

 

 

 

transmitter manufacturer and d is the

 

 

 

recommended separation distance in meters

 

 

 

(m).

 

 

 

Field strengths from fixed RF transmitters, as

 

 

 

determined by an electromagnetic site

 

 

 

survey,a should be less than the compliance

 

 

 

level in each frequency range.b

 

 

 

Interference may occur in the vicinity of

 

 

 

equipment marked with the following symbol:

 

 

 

 

NOTE 1: At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2: These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.

aField strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the VPAP Adapt SV is used exceeds the applicable RF compliance level above, the VPAP Adapt SV should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the VPAP Adapt SV.

bOver the frequency range 150 kHz to 80 MHz, field strengths should be less than 10 V/m.

38

Page 38
Image 38
ResMed VPAP Adapt SV manual Portable and mobile RF communications

VPAP Adapt SV specifications

The ResMed VPAP Adapt SV is a cutting-edge device designed to improve the quality of life for patients suffering from complex sleep apnea conditions, including central and obstructive sleep apnea. It combines advanced technology with user-friendly features to provide effective therapy while ensuring maximum comfort for users.

A standout feature of the VPAP Adapt SV is its Adaptive Servo-Ventilation (ASV) algorithm. This proprietary technology continuously monitors a patient’s breathing patterns and adjusts the airflow accordingly. By providing just the right amount of pressure support during inhalation and maintaining a minimal backup rate during exhalation, the device ensures optimal ventilation while minimizing the risk of over-ventilation. This responsiveness is crucial for patients who may experience fluctuating airway resistance and varying degrees of respiratory events.

The VPAP Adapt SV is equipped with a sophisticated data management system that tracks treatment progress in real time. It automatically collects information about usage, leak rates, and overall pressure settings, which can be easily accessed and reviewed by healthcare providers. This data-driven approach facilitates personalized treatment adjustments, empowering both patients and clinicians to make informed decisions.

Comfort is enhanced through various design features, including a quiet operation mechanism that minimizes noise disruption during sleep. The device offers a range of pressure settings that can be tailored to individual needs, allowing for a comfortable therapeutic experience. The VPAP Adapt SV is compatible with ResMed’s range of CPAP masks, which are ergonomically designed to fit securely without compromising comfort.

Another notable characteristic is its user-friendly interface, which simplifies the setup and adjustments needed for optimal therapy. Patients can easily navigate through various options on the bright display screen, making it accessible for users of all ages.

Additionally, the VPAP Adapt SV’s compact design makes it a portable option for those who travel frequently. It comes with a carrying case and can operate on both AC and DC power sources, ensuring that patients can maintain their therapy wherever they go.

In conclusion, the ResMed VPAP Adapt SV represents a significant advancement in respiratory therapy. With its Adaptive Servo-Ventilation technology, comprehensive data management, and focus on patient comfort, it provides a holistic approach to managing complex sleep apnea, making it a preferred choice for healthcare providers and patients alike.