Rheem 07EAUER, 05EAUER manual Downflow Dimensions, Model, REDUCED CLEARANCES IN. mm, Rglh, LBS. kg

Models: 05EAUER 05NAUER 07EAUER 07NAUER

1 8
Download 8 pages 5.42 Kb
Page 4
Image 4
DOWNFLOW DIMENSIONS

DOWNFLOW DIMENSIONS

TABLE 1. DIMENSIONS AND CLEARANCE TO COMBUSTIBLE MATERIAL (INCHES) [mm]

MODEL

 

 

 

 

 

 

 

 

REDUCED CLEARANCES (IN.) [mm]

 

 

RGLH-

 

A

B

C

D

E

LEFT

RIGHT

BACK

TOP

FRONT

VENT

SHIP. WGTS.

SERIES

 

 

 

 

 

 

SIDE

SIDE

(LBS.) [kg]

 

 

 

 

 

 

 

 

 

 

05

14

[356]

1227/32 [326]

103/8 [264]

131/8 [333]

0

4

0

1 [25]

3 [76]

6 [152]

85

[38.6]

07

171/2 [445]

1611/32 [415]

121/8 [308]

165/8 [422]

0

3

0

1 [25]

3 [76]

6 [152]

105

[47.6]

10 (A)

171/2 [445]

1611/32 [415]

121/8 [308]

165/8 [422]

0

3

0

1 [25]

3 [76]

6 [152]

115

[52.2]

10 (B)

21

[533]

1927/32 [504]

137/8 [352]

201/8 [511]

0

0

0

1 [25]

3 [76]

6 [152]

120

[54.4]

12

241/2 [622]

2311/32 [593]

155/8 [397]

235/8 [600]

0

0

0

1 [25]

3 [76]

6 [152]

140

[63.5]

15

241/2 [622]

2311/32 [593]

155/8 [397]

235/8 [600]

0

0

0

1 [25]

3 [76]

6 [152]

150

[68]

NOTES: May require a 3" [76 mm] to 4" [102 mm] or 3" [76 mm] to 5" [127 mm] adapter.

May be 0" [0 mm] with type B vent.

May be 1" [25 mm] with type B vent.

Furnaces must be vented in accordance with ANSI Z21.47-1993CAN/CGA-2.3-M93 venting table guidelines, and in accordance with local codes.

4

[ ] Designates Metric Conversions

Rheem Manufacturing Company

Page 4
Image 4
Rheem 07EAUER, 05EAUER, 05NAUER, 07NAUER manual Downflow Dimensions, Model, REDUCED CLEARANCES IN. mm, Rglh, LBS. kg

FAQ

What are the downflow dimensions for Rheem furnace models 07NAUER, 07EAUER, 05NAUER, 05EAUER?

The downflow dimensions for these models can be found in the table provided on the official manual page.

Do the furnaces need to be vented in a specific way?

Yes, the furnaces must be vented in accordance with ANSI Z21.47-1993/CAN/CGA-2.3-M93 venting table guidelines, and in accordance with local codes.

Are there any specific adapters required for venting?

Depending on the type of vent, an adapter may be required, such as a 3" to 4" or 3" to 5" adapter.