Rheem-Ruud AdvantagePlus
RECOVERY CAPACITIES
MODEL |
|
|
|
|
|
| TEMPERATURE RISE - DEGREES F - GALLONS PER HOUR |
|
|
| ||||
NUMBER | CAPACITY | INPUT | EFFICIENCY | 40° | 50° | 60° | 70° | 80° | 90° | 100° | 110° | 120° | 130° | 140° |
45 | 100,000 | 95% | 288 | 230 | 192 | 165 | 144 | 128 | 115 | 105 | 96 | N/A | N/A | |
45 | 130,000 | 95% | 374 | 299 | 249 | 214 | 187 | 166 | 150 | 136 | 125 | N/A | N/A | |
80 | 130,000 | 95% | 374 | 299 | 249 | 214 | 187 | 166 | 150 | 136 | 125 | N/A | N/A | |
119 | 130,000 | 95% | 374 | 299 | 249 | 214 | 187 | 166 | 150 | 136 | 125 | N/A | N/A | |
45 | 160,000 | 95% | 461 | 368 | 307 | 263 | 230 | 205 | 184 | 167 | 154 | 142 | 132 | |
80 | 160,000 | 95% | 461 | 368 | 307 | 263 | 230 | 205 | 184 | 167 | 154 | N/A | N/A | |
119 | 160,000 | 95% | 461 | 368 | 307 | 263 | 230 | 205 | 184 | 167 | 154 | N/A | N/A | |
45 | 199,000 | 95% | 573 | 458 | 382 | 327 | 286 | 255 | 229 | 208 | 191 | 176 | 164 | |
80 | 199,000 | 95% | 575 | 460 | 384 | 329 | 288 | 256 | 230 | 209 | 192 | N/A | N/A | |
119 | 199,000 | 95% | 575 | 460 | 384 | 329 | 288 | 256 | 230 | 209 | 192 | N/A | N/A |
Recovery rating is based on a recovery efficiency obtained in an UL laboratory.
This model exceeds the minimum NAECA energy factor requirements of ASHRAE
MAXIMUM DELIVERY (in gallons) (Includes useable storage and recovery for indicated times)
MODEL |
|
|
|
| TEMP. | 5 | 10 | 15 | 20 | 30 | 45 | 1 | 2 | 3 | MIN. TO RECOVER | |
NUMBER | CAPACITY | INPUT | EFFICIENCY | RISE | MIN. | MIN. | MIN. | MIN. | MIN. | MIN. | HR. | HR. | HR. | CONTENTS | ||
45 | 100,000 |
| 95% | 100° | 41 | 51 | 60 | 70 | 89 | 118 | 147 | 262 | 377 | 23 | ||
45 | 130,000 |
| 95% | 100° | 44 | 56 | 69 | 81 | 106 | 144 | 181 | 331 | 481 | 18 | ||
80 | 130,000 |
| 95% | 100° | 68 | 81 | 93 | 106 | 131 | 168 | 206 | 355 | 505 | 32 | ||
119 | 130,000 |
| 95% | 100° | 96 | 109 | 121 | 134 | 159 | 196 | 234 | 383 | 533 | 48 | ||
45 | 160,000 |
| 95% | 100° | 47 | 62 | 78 | 93 | 124 | 170 | 216 | 400 | 584 | 15 | ||
80 | 160,000 |
| 95% | 100° | 71 | 87 | 102 | 117 | 148 | 194 | 240 | 424 | 609 | 26 | ||
119 | 160,000 |
| 95% | 100° | 99 | 115 | 130 | 145 | 176 | 222 | 268 | 452 | 637 | 39 | ||
45 | 199,000 |
| 95% | 100° | 51 | 70 | 89 | 108 | 146 | 203 | 261 | 490 | 719 | 12 | ||
80 | 199,000 |
| 95% | 100° | 75 | 94 | 114 | 133 | 171 | 229 | 286 | 516 | 747 | 21 | ||
119 | 199,000 |
| 95% | 100° | 103 | 122 | 141 | 161 | 199 | 257 | 314 | 544 | 774 | 31 | ||
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DIMENSIONAL INFORMATION (All dimensions shown in inches) |
|
|
|
|
|
|
|
|
|
| ||||||
MODEL |
|
|
|
|
|
| APPROX. SHIPPING |
|
|
|
|
|
|
| ||
NUMBER | HEIGHT | WIDTH | DEPTH | VENT |
| WEIGHT (LBS.) |
|
|
|
|
|
|
|
| ||
42 | 32 | 2 † |
|
| 175 |
|
|
|
|
|
|
|
| |||
42 | 32 | 2 † |
|
| 175 |
|
|
|
|
|
|
|
| |||
42 | 32 | 3 |
|
| 175 |
|
|
|
|
|
|
|
| |||
42 | 32 | 3 |
|
| 175 |
|
|
|
|
|
|
|
| |||
72 | 32 | 2 † |
|
| 235 |
|
|
|
|
|
|
|
| |||
72 | 32 | 3 |
|
| 235 |
|
|
|
|
|
|
|
| |||
72 | 32 | 3 |
|
| 235 |
|
|
|
|
|
|
|
| |||
73 |
| 27 | 36 | 2 † |
|
| 405 |
|
|
|
|
|
|
|
| |
73 |
| 27 | 36 | 3 |
|
| 405 |
|
|
|
|
|
|
|
| |
73 |
| 27 | 36 | 3 |
|
| 405 |
|
|
|
|
|
|
|
|
†Models with inputs of 100,000 kBtu and 130,000 kBtu are certified to vent with 2” Schedule 40 PVC, CPVC or ABS pipe.
CLEARANCES TO COMBUSTIBLES
MODEL | REAR / |
|
|
NUMBER | SIDES | FRONT* | TOP |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 | |
0 | 0 | 0 |
* 24" service clearance recommended