VentMaster continued.
RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at various temperature rises.
| MODEL | INPUT |
| 40°F |
| 50°F |
| 60°F |
| 70°F |
| 80°F |
| 90°F |
| 100°F |
| 110°F |
| 120°F |
| 130°F |
| 140°F |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
| NUMBER | BTU/HR. | UNITS | (22°C) |
| (28°C) |
| (33°C) |
| (39°C) |
| (45°C) |
| (50°C) |
| (56°C) |
| (61°C) |
| (67°C) |
| (72°C) |
| (78°C) |
|
| 150,000 | GPH | 364 |
| 291 |
| 242 |
| 208 |
| 182 |
| 161 |
| 146 |
| 132 |
| 122 |
| 112 |
| 104 |
| |
|
|
| LPH | 1380 |
| 1103 |
| 917 |
| 788 |
| 690 |
| 610 |
| 553 |
| 500 |
| 462 |
| 424 |
| 394 |
|
| 199,900 | GPH | 485 |
| 388 |
| 323 |
| 277 |
| 242 |
| 215 |
| 194 |
| 176 |
| 162 |
| 149 |
| 138 |
| |
|
|
| LPH | 1838 |
| 1471 |
| 1224 |
| 1050 |
| 917 |
| 815 |
| 735 |
| 667 |
| 45 |
| 565 |
| 523 |
|
| 250,000 | GPH | 606 |
| 485 |
| 404 |
| 346 |
| 303 |
| 269 |
| 242 |
| 220 |
| 202 |
| 186 |
| 173 |
| |
|
|
| LPH | 2294 |
| 1835 |
| 1529 |
| 1311 |
| 1147 |
| 1020 |
| 918 |
| 834 |
| 765 |
| 706 |
| 655 |
|
MAXIMUM DELIVERY In U.S. Gallons and Liters. (Includes useable storage and recovery for indicated times.)
CLEARANCE TO COM-
BUSTIBLES (inches and mm)
MODEL |
|
|
|
NUMBER | SIDE | REAR | TOP |
2" | 6" | 18" | |
51mm | 153mm | 459mm | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Minutes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
MODEL | TANK CAP. |
| INPUT | TEMP. |
|
|
|
| 5 |
| 10 |
| 15 |
| 20 | 30 |
| 45 | 60 |
| to Rec. |
| |||||||
NUMBER | GALLONS |
| BTU/HR. | RISE |
| UNITS |
| Min. |
| Min. |
| Min. | Min. | Min. |
| Min. | Min. |
| Contents |
| |||||||||
100 |
|
| 150,000 | 100 °F |
| GAL |
| 82 |
| 94 |
| 106 | 119 | 143 |
| 179 | 216 |
| 40 |
| |||||||||
|
|
|
|
|
|
| 37.7 °C |
| LTR |
| 311 |
| 356 |
| 402 |
| 451 | 542 |
| 678 | 819 |
|
|
| |||||
100 |
|
| 199,900 | 100 °F |
| GAL |
| 86 |
| 102 |
| 118 | 135 | 167 |
| 215 | 264 |
| 31 |
| |||||||||
|
|
|
|
|
|
| 37.7 °C |
| LTR |
| 326 |
| 387 |
| 448 |
| 510 | 632 |
| 815 | 999 |
|
|
| |||||
100 |
|
| 250,000 | 100 °F |
| GAL |
| 90 |
| 110 |
| 131 | 151 | 191 |
| 252 | 312 |
| 25 |
| |||||||||
|
|
|
|
|
|
| 37.7 °C |
| LTR |
| 341 |
| 418 |
| 494 |
| 571 | 724 |
| 953 | 1183 |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
DIMENSIONAL | INFORMATION All dimensions in English and Metric units. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
| A |
| B | C |
| D |
| E |
| F |
| G |
| WATER |
| CONNECTIONS | APPROXIMATE |
| |||||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||||
MODEL |
|
|
|
|
|
|
|
| FRONT |
|
| REAR | SHIPPING |
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
| WEIGHT |
| |||||||||||||||||
NUMBER |
| UNITS |
|
|
|
|
|
| IN/OUT |
|
|
| SIDE |
|
| ||||||||||||||
| inches |
|
| 3 |
| 59 |
| 3/4 |
| 2 |
|
|
| 2 |
| 860 lbs. |
| ||||||||||||
| mm | 2076 |
| 1734 | 768 | 629 |
| 76 |
| 1499 |
| 19 |
| 51 |
|
|
| 51 |
|
| 390 kgs. |
| |||||||
| inches |
|
| 4 |
| 59 |
| 3/4 |
| 2 |
|
|
| 2 |
| 860 lbs. |
| ||||||||||||
| mm | 2076 |
| 1734 | 768 | 629 |
| 101 |
| 1499 |
| 19 |
| 51 |
|
|
| 51 |
|
| 390 kgs. |
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
(A) Suffix Indicates ASME Tank Construction Available.
E
C | B |
Rear dimension, add 4" (102mm) clearance for intake
FA
D
G
Recommended Specifications:
Water heater(s) shall be model _______________________, manufactured by
of ___________ GPH at a 100°F temperature rise. Water heater shall have a storage capacity of ______________ gallons. Water heater shall have the CSA seal of
certification and be factory equipped with an AGA/ASME rated temperature and pressure relief valve. Tank shall have a coating of high temperature porcelain enam- el and furnished with a magnesium anode rod rigidly supported. Water heater shall meet or exceed the energy factor requirements of ASHRAE. Tank shall have a working pressure rating of 150 psi, and shall be completely factory assembled, including a pressure regulator properly adjusted for operation on natural gas with a stainless steel burner. Water Heater shall have a
safety shutoff in event of pilot failure. Complete unit shall be insulated with fiberglass insulation. Water Heater shall be covered by a three year limited warranty against tank leaks.
•Add for ASME construction – water heaters shall be constructed in accordance with the requirements or the ASME Boiler and Pressure Vessel Code, Section IV Part HLW.
Limited Warranty:
This product features a three year limited warranty against tank leaks. Please refer to Commercial Warranty Information brochure for complete warranty information.
C O M M E R C I A L W A T E R H E A T E R S
In keeping with its policy of continuous progress and product improvement,
Rheem Water Heating • 101 Bell Road, Montgomery, Alabama
Rheem Canada Ltd./Ltée,128 Barton Street West, Hamilton, Ontario L8N 3P3
P R I N T E D I N U. S . A | 1 1 / 0 6 W P | F O R M N O. R R 1 0 2 C - 1 6 R ev. 4 |