TYPICAL INSTALLATION – OUTDOOR LOCATION
Gas Details Hourly Gas
Consumption (MJ) Min. Gas
Pressure (kPa) Test Point Gas
Pressure (kPa) Max. Gas
Pressure (kPa)
090 135 170 090 to 170 090 135 170 090 to 170
Natural 30 35 40 1.13 1.00 1.00 1.00 3.50
Propane 30 35 40 2.75 2.70 2.70 2.70 3.50
Butane 30 30 30 2.75 2.70 2.70 2.70 3.50
Town / TLP 27/25 32/30 38/35 0.75 0.45 0.40 0.35 3.50
Model numbers: N = Natural, P = Propane, B = Butane, T = Town / TLP. Letter N, P, B or T is
included in the model number, eg 311135N0, to denote gas type.
Specifications are subject to change with ongoing product improvements.