Rheem Gas Hot Water Supply Heaters Recovery Capacities, General Flow And Piping Specifications

Models: Gas Hot Water Supply Heaters

1 6
Download 6 pages 16.22 Kb
Page 5
Image 5
RECOVERY CAPACITIES

RECOVERY CAPACITIES

MODEL NUMBER

STYLE

INPUT BTU/Hr.

 

TEMPERATURE RISE – DEGREES F – GALLONS PER HOUR

 

wo/Pump

w/Pump

Indoor

Outdoor

NATURAL

40°

50°

60°

70°

80°

90°

100°

110°

120°

130°

140°

GBB136

GBBP136

*

*

136,000

330

264

220

188

165

147

132

120

110

101

94

GBC186

GBCP186

*

*

181,000

440

352

293

251

220

195

176

160

147

135

126

GBC264

GBCP264

*

*

264,000

640

512

427

366

320

284

256

233

213

197

183

GBC331

GBCP331

*

*

334,000

811

649

541

463

406

360

324

295

270

250

232

GBC399

GBCP399

*

*

399,000

967

774

645

553

484

430

387

352

322

298

276

GBC512

GBCP512

*

*

511,500

1240

992

827

709

620

551

496

451

413

382

354

GBC627

GBCP627

*

*

627,000

1520

1216

1013

869

760

676

608

553

507

468

434

GBC726

GBCP726

*

*

726,000

1760

1408

1173

1006

880

782

704

640

587

542

503

GBC825

GBCP825

*

*

825,000

2000

1600

1333

1143

1000

889

800

727

667

615

571

GBC926

GBCP926

 

*

926,000

2245

1796

1497

1283

1122

998

898

816

748

691

641

GBC962

GBCP962

*

 

961,700

2331

1865

1554

1332

1166

1036

933

848

777

717

665

GBC1083

GBCP1083

 

*

1,083,000

2625

2100

1750

1500

1313

1167

1050

955

875

808

750

GBC1125

GBCP1125

*

 

1,124,700

2727

2181

1818

1558

1363

1212

1091

991

909

839

779

GBC1178

GBCP1178

 

*

1,178,000

2856

2285

1904

1632

1428

1269

1142

1038

952

879

816

GBC1223

GBCP1223

*

 

1,222,500

2964

2371

1976

1694

1482

1317

1185

1078

988

912

847

GBC1287

GBCP1287

 

*

1,287,000

3120

2496

2080

1783

1560

1387

1248

1135

1040

960

891

GBC1337

GBCP1337

*

 

1,336,600

3240

2592

2160

1852

1620

1440

1296

1178

1080

997

926

GBC1413

GBCP1413

 

*

1,413,000

3425

2740

2284

1957

1713

1522

1370

1246

1142

1054

979

GBC1467

GBCP1467

*

 

1,467,000

3556

2845

2371

2032

1778

1581

1423

1293

1185

1094

1016

GBC1570

GBCP1570

 

*

1,570,000

3806

3045

2537

2175

1903

1692

1522

1384

1269

1171

1087

GBC1630

GBCP1630

*

 

1,630,000

3952

3161

2634

2258

1976

1756

1581

1437

1317

1216

1129

GBC1758

GBCP1758

 

*

1,758,000

4262

3409

2841

2435

2131

1894

1705

1550

1421

1311

1218

GBC1826

GBCP1826

*

 

1,825,600

4426

3541

2950

2529

2213

1967

1770

1609

1475

1362

1264

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL FLOW AND PIPING SPECIFICATIONS

 

 

 

 

 

 

 

 

 

Water Hardness

 

 

 

 

 

 

MODELS

 

 

SOFT

 

 

 

 

 

MEDIUM

 

 

 

 

HARD

 

 

 

 

 

0-4 Grains Per Gallon

 

 

5-15 Grains Per Gallon

 

16 & Over Grains Per Gallon

Indoor

Outdoor

T

GPM

P

MPS

 

SHL

T

GPM

 

P

 

MPS

SHL

T

GPM

P

MPS

SHL

136

136

22

10

3.4

1-1/4

 

5.09

17

13

 

5.5

 

1-1/4

8.2

10

22

14.7

1-1/4

22

186

186

15

20

1.82

1-1/2

 

4.48

11

26

 

3

 

1-1/2

7.5

7

40

6.8

1-1/2

17

264

264

21

20

1.85

1-1/2

 

4.51

16

26

 

3.1

 

1-1/2

7.6

10

42

8.3

1-1/2

18.8

331

331

27

20

1.9

1-1/2

 

4.56

20

26

 

3.2

 

1-1/2

7.7

13

42

8.5

1-1/2

19

399

399

30

22

2.1

1-1/2

 

5.08

25

26

 

3.3

 

1-1/2

7.8

15

43

9

1-1/2

19.5

512

512

20

42

1.8

2

 

4.4

16

52

 

2.9

 

2

7

10

84

6.8

2

16.6

627

627

25

41

1.9

2

 

4.5

19

54

 

3.1

 

2

7.2

11

90

8.5

2

20.4

726

726

29

41

2

2

 

4.6

20

60

 

4

 

2

9.3

13

90

9

2

20.8

825

825

30

45

2.5

2

 

5.7

20

68

 

5.2

 

2

11.7

15

90

9.3

2

21.1

962

926

30

53

3.5

2-1/2

 

4.9

20

79

 

7.5

 

2-1/2

10.5

17

90

10.1

2-1/2

14.3

1125

1083

30

61

5.5

2-1/2

 

7.5

20

90

 

11.8

 

2-1/2

16

20

90

11.8

2-1/2

16

1223

1178

30

67

6.5

2-1/2

 

8.8

22

90

 

12

 

2-1/2

16.2

22

90

12

2-1/2

16.2

1337

1287

30

73

8.4

2-1/2

 

11

24

90

 

13.3

 

2-1/2

17.5

24

90

13.3

2-1/2

17.5

1467

1413

30

80

10.8

2-1/2

 

14.1

26

90

 

13.8

 

2-1/2

18

26

90

13.8

2-1/2

18

1630

1570

30

89

13.7

2-1/2

 

17.6

29

90

 

14.8

 

2-1/2

19

29

90

14.8

2-1/2

19

1826

1758

32

90

15.5

2-1/2

 

19.7

32

90

 

15.5

 

2-1/2

19.7

32

90

15.5

2-1/2

19.7

NOTE: Additional pipe fittings will increase the system head loss. Select a pump based on the water hardness, flow and system head loss. If water heater is more than two stories above the tank, consult the pump manufacturer.

T

– Temperature Rise, Degree F @ GPM Flow

GPM

– Gallons per Minute Flow

P

– Pressure Drop, Ft. thru Heat Exchanger

MPS

Minimum Pipe Size, NPT

SHL

System Head Loss

 

 

 

Sizing based on water heater and tank being placed 5 feet apart. The equivalent length of pipe valves and fittings in the system is as follows.

1-1/4" NPT = 65 Ft (136)

1-1/2" NPT = 70 Ft (186-399)

2" NPT = 75 Ft (512-825)

2-1/2" NPT = 80 Ft (926-1826)

Page 5
Image 5
Rheem Gas Hot Water Supply Heaters warranty Recovery Capacities, General Flow And Piping Specifications, INPUT BTU/Hr, Hard