Section IV: Installation
water connections
All piping between the boiler and the indirect water heater should be new copper with a minimum size of 3/4” ID for models STID30, STID40, and STID50. Use 1” minimum copper for models STID80 and STID120. Elbows should be minimized. A flow check valve must be installed on the return line.
All piping to the inlet (cold) and outlet (hot) domestic water connections should be new copper with a minimum size of 1/2” ID for models STID30, STID40, and STID50. Use 3/4” ID minimum for models STID80 and STID120.
All piping should conform to local codes and ordinances. At a minimum, refer to ILHR 84 code if local codes are not in place. It is recommended that all piping be adequately insulated with approved material to ensure minimum heat loss. If a
See Figures 6 and 7 for proper water connection installation.
|
| BOILER |
3/4" | 3/4" | SYSTEM |
SUPPLY | ||
DOMESTIC | COLD | CIRCULATOR |
HOT OUT | INLET | PUMP |
INDIRECT
WATER HEATER
FROM BOILER 1" NPT
TO | CHECK |
BOILER | |
1" NPT | VALVE |
BOILER
BOILER
SYSTEM
RETURN
BOILER
SYSTEM
SUPPLY
CIRCULATOR
PUMP
Figure 6: STID30, STID40, STID50 water connections | 1 1/2" |
|
|
| |
| DOMESTIC |
|
| HOT OUT |
|
|
| INDIRECT |
|
| WATER HEATER |
|
| FROM |
|
| BOILER |
NOTICE: Indirect water heater may be connected to a steam | 1" NPT | |
| ||
boiler provided that all piping to and from | 1" |
|
the boiler are below the water line of the boiler. | COLD |
|
INLET | TO | |
Boiler must also be protected by a low water |
| BOILER |
| 1" NPT |
cut off safety device.
BOILER
BOILER
SYSTEM
CHECKRETURN VALVE
Figure 7: STID80, STID120 water connections
Page 9