Water$Temperature$Setting…
Maximum'water'temperature'occurs'while''
the'burner'is'on.'To'determine'the'water'
temperature,'turn'on'a'hot'water'faucet'and'
place'a'thermometer'in'the'water'stream.'
Water'temperature'at'the'faucet'may'vary'
depending'on'season'and'length'of'pipe''
from'the'water'heater.
The'factory'setting'of'the'remote'control'
temperature'range'is'between'100°F'(38°C)'
and'120°F'(49°C).
The'remote'control'is'factory'preset'to'100°F'
(38°C).''To'turn'the'remote'control'ON'or'
OFF,'press'the'POWER'button.
To'adjust'the'temperature'to'a'required'
setting,'press'the'UP'arrow'temperature'
button.
Pressing'the'UP'or'DOWN'temperature'
adjustment'buttons'will'change'the'
temperature'set'point.
The'temperature'set'point'on'the'remote'
control'cannot'be'increased'above'112°F'
(44°C)'when'a'hot'water'faucet'is'in'the''
open'position.
Notice:'The'factory'setting'allows'operating'
temperatures'between'100°F'(38°C)'and'
120°F'(49°C).'Temperatures'of'85°F'(29°C)'
and'up'to'140°F'(60°C)'can'be'achieved'
with'the'MAIN'(UMCE117)'remote'control.'
Temperatures'of'85°F'(29°C)'can'be'
achieved'with'the'Bath'(USCE117'or'
USC2E117)'remote'control.'Only'qualified'
service'personnel'should'perform'this'
adjustment.'Only'factory'authorized'remote'
control(s)'should'be'used.
The'hottest'temperature'water'will'be'at'the'
hot'water'faucet'closest'to'the'water'heater.
Always'remember'to'test'the'water'
temperature'with'your'hand'before'use'and'
remember'that'hotter'water'increases'the'risk'
of'scald'injury.
Always'supervise'young'children'or'others'
who'are'incapacitated.
The'water'heater'is'equipped'with'a'device'
that'will'shut'off'the'gas'supply'to'the'burner'
if'the'water'heater'exceeds'normal'operating'
temperatures.'Refer'to'the'“Before'You'Call'
For'Service”'section'located'near'the'back'of'
this'manual,'or'contact'your'dealer.
!WARNING:$Should$overheating$
occur$or$the$gas$supply$fail$to$shut$off,$$
turn$off$the$manual$gas$control$valve$$
to$the$appliance.
If'the'water'heater'has'been'subjected'to'
fire,'flood,'physical'damage,'or'has'been'
under'water,'turn'off'the'manual'gas'shutEoff'
valve(s),'and'do'not'operate'the'water'heater'
again'until'it'has'been'checked'by'qualified'
personnel.
Notice:'The'water'heater'may'not'operate'
with'a'small'water'flow.'In'such'case,'increase'
the'water'flow.'If'water'heater'still'does'not'
operate'and'hot'water'faucet'is'completely'
open,'increase'the'temperature'setting'on'the'
remote'control.
°F
PRIORITY
POWER
ON/OFF
Higher'(Hotter)' Lower'(Cooler)'
''100'102'104'106'108'110'112'114'116'118'120*
'''38'''39'''40'''41'''42'''43'''44'''46'''47'''48'''49*
85
29
125'130'140'°F
52'''54'''60'
°C
*'''Temperatures'85°F'(29°C)'and'up'to'140°F'(60°C)'can'be'achieved'with'the'MAIN'
(UMCE117)'remote'control.'See'page'34'and'35'for'maximum'and'minimum'
temperature'adjustment.
In'Use'Indicator'
(Lit'during'operation)
LED'Display'
(Displays'water'temperature'and'error'codes)
ON/OFF'
Indicator
Temperature'
Adjustment'
Buttons
Priority'Indicator
Notice:$The'remote'
control'cannot'be'
turned'on'when'
water'is'flowing'or'
circulating'through'the'
water'heater.
Notice:$Display'shows'°F'only.