The$content$on$this$page$is$intended$ for$use$by$qualified$$
installation/service$personnel$ONLY.
WARNING:$Improper$adjustment,$altera`
tion,$service$or$maintenance$can$cause$prop`
erty$damage,$personal$injury,$or$death.
Minimum$Temperature$Adjustment$by$the$
Main$Remote$Control$(UMC`117,$USC1`117$
and$USC2`117)
Required$adjustment$for$85°F$(29°C)$water$
temperature$setting.
Follow'the'instruction'below'if'it'is'determined'that'a'
setting'of'85°F'(29°C)'is'required.
Turn'on'the'remote'control.'Turn'off'the'gas'and'
water'shutoff'valves.
Press'the'Down'arrow'temperature'adjustment'butE
ton'on'the'remote'control'for'several'times'and'set'
the'temperature'at'100°F'(38°C).
'Press'the'Down'button'on'remote'control'3'times'
within'5'seconds.'The'display'of'the'remote'conE
trol'will'show'“85”.''
Turn'on'the'gas'and'water'shut'off'valves.
'Check'and'ensure'safe'operation'and'performance'
of'the'water'heater.
NOTICE:$7KHPD[LPXPÀRZUDWHDW)&LV
1.3'gpm'(5.0'l/m).
High$Altitude$DIP$Switch$Adjustment
For$High$Altitude$Installation$above$3,280$
Feet$(1,000m):
When'the'water'heater'is'installed'above'3,280'feet'
(1,000m),'the'adjustment'of'DIP'switch'is'required'for'
high'altitude'installation.
Without'adjusting'the'DIP'switch,'the'water'heater'
may'not'function'properly.
NOTICE:$If$the$water$heater$is$installed$less$than$
3,280$feet$(1,000m),$no$action$is$required.
How'to'adjust'the'DIP'switch'on'the'PCB'for'high'
altitude'installation:
'Check'the'altitude'(above'sea'level)'where'the'
water'heater'is'installed.
'If'the'altitude'is'more'than'3,280'feet'(1,000m),'
the'adjustment'of'DIP'switch'is'required.
'Turn'off'the'gas'shut'off'valve'and'water'shutoff'
valve.
Remove'the'front'cover.
'Find'the'two'DIP'switches'located'at'the'top'right'
hand'side'of'the'PCB.''The'switch'labeled'"DIP'2"'
is'the'bottom'switch.
'Change'the'DIP'switch'#3'setting'of'DIP'2'to'
“ON”'position'if'the'water'heater'is'installed'
above'3,280'feet'(1,000m)'below'6,560'feet'
(2,000m).'See'the'diagram'below.'DO'NOT'alter'
any'other'DIP'Switch.''
'Change'the'DIP'switch'#4'setting'of'DIP'2'to'
“ON”'position'if'the'water'heater'is'installed'
above'6,560'feet'(2,000m)'below'9,840'feet'
(3,000m).'See'the'diagram'below.'DO'NOT'alter'
any'other'DIP'Switch.
NOTICE:$$Manifold$pressure$will$be$reduced$by$
this$adjustement.
Attach'the'unit’s'front'cover.
'Turn'on'the'gas'shutoff'valve'and'water'shutoff'
valve.
'Check'and'ensure'safe'operation'and'performance'
of'the'water'heater.
Location'of'DIP'Switches'on'PC'Board.
Dip switch adjustment
3,280 feet (1,000m)
thru
6,560 feet (2,000m)
ON
1234
As set from factory
ON
1234
ON
1234
Dip switch adjustment
6,560 feet (2,000m)
thru
9,840 feet (3,000m)
ON
1234
DIP2
ONOFF
1234
DIP
Switches
PCB