Open the upper charge faucet and allow the pressure from the expansion tank to push the water in the glycol loop back to prime the pressure pump. When the hose in the bucket containing the glycol mixture stops bubbling you may begin charging the collector loop with glycol.

With both charge faucets now open, run the Flojet pressure pump until the pinkish glycol mixture begins flowing into the empty bucket. Quickly switch the hose from the empty/return bucket to the bucket containing the glycol mixture. Continue to circulate the fluid using the pressure pump until the bubbling has stopped and the air has been purged.

4.11.5After charging the collector loop, shut the lower charge faucet and let the pressure pump drive up the loop pressure to the appropriate level (Generally in the range of 25 PSI). To more accurately calculate the proper pressure measure the height of the solar collector above the solar storage tank and divide this number by 2.31. Then add 20 PSI to this number. As a word of caution, the pressure in the glycol

loop should not exceed 45 PSI when the system is

operational on a good sunny day. Contact your solar contractor if the charged collector loop pressure exceeds this threshold.

Your Rheem solar water heating system must be charged and the fluid quality maintained by an experienced contractor. If the system is drained during the winter, or you notice a significant drop in collector loop pressure, contact your installation contractor immediately for service. The glycol HTF provides the freeze protection for your system and must be properly maintained. An experienced contractor should periodically check the HTF fluid quality.

4.11.6 Dowfrost HD HTF

To ensure maximum effectiveness for corrosion protection, the glycol inhibitor package is designed for a minimum 25-30 percent concentration of glycol in water. Table 4 shows the concentrations of Dowfrost HD required to provide freeze and burst protection at various temperatures. Use the mixture most appropriate for your climate. Do not use a higher glycol to water concentration than necessary,