RH5RH

ELECTRICAL CHARACTERISTICS

 

 

 

 

 

 

 

• RH5RH301A

 

 

 

 

 

 

VOUT=3.0V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Symbol

 

Item

Conditions

MIN.

TYP.

MAX.

Unit

 

Note

 

 

 

 

 

 

 

 

 

 

 

 

VOUT

 

Output Voltage

 

2.925

3.000

3.075

V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VIN

 

Input Voltage

 

 

 

8

V

 

 

 

 

 

 

IOUT=1mA,VIN : 0→2V

 

 

 

 

 

 

 

Vstart

 

Start-up Voltage

 

0.8

0.9

V

 

 

 

 

 

 

IOUT=1mA,VIN : 2→0V

 

 

 

 

 

 

 

Vhold

 

Hold-on Voltage

0.7

 

 

V

 

 

 

 

 

 

To be measured at OUT Pin

 

 

 

 

 

 

 

IDD1

 

Supply Current 1

 

15

25

µA

 

 

 

 

(excluding Switching Current)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To be measured at OUT Pin

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IDD2

 

Supply Current 2

(excluding Switching Current)

 

2

5

µA

 

 

 

 

 

 

VIN=3.5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ILX

 

Lx Switching Current

VLX=0.4V

60

 

 

mA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ILXleak

 

Lx Leakage Current

VLX=6V,VIN=3.5V

 

 

0.5

µA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fosc

 

Oscillator Frequency

 

40

50

60

kHz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maxdty

 

Oscillator Maximum Duty

on (VLX “L” ) side

70

80

90

%

 

 

 

 

Cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

η

 

Efficiency

 

70

85

 

%

 

 

 

 

 

 

Time required for the rising

 

 

 

 

 

 

 

tstart

 

Soft-Start Time

0.5

2.0

 

ms

 

Note1

 

 

of VOUT up to 3V.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VLXlim

 

VLX Voltage Limit

Lx Switch ON

0.65

0.8

1.0

V

 

Note2

 

 

 

 

 

 

 

 

 

 

 

 

Unless otherwise provided, VIN=1.8V, VSS=0V, IOUT=10mA, Topt=25˚C, and use External Circuit of Typical

Application (FIG. 1).

(Note 1) Soft-Start Circuit is operated in the following sequence :

(1)VIN is applied.

(2)The voltage (Vref) of the reference voltage unit is maintained at 0V for about 200µs after the application of VIN.

(3)The output of Error Amp. is raised to “H” level during the maintenance of the voltage (Vref) of the reference voltage unit.

(4)After the rise of Vref, the output of Internal Error Amp. is gradually decreased to an appropriate value by the function of Internal Phase Compensation Circuit, and the Output Voltage is gradually increased in accordance with the gradual decrease of the output of Internal Error Amp.

(Note 2) ILX is gradually increased after Lx Switch is turned ON. In accordance with the increase of ILX, VLX is also increased. When VLX reaches VLXlim, Lx Switch is turned OFF by an Lx Switch Protection Circuit.

5