TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
Air receiver pressure drops when com- | Loose connections (fittings, tubing, | Check all connections with soap and |
pressor shuts off | etc.) | water solution and tighten |
| Loose drain valve | Tighten drain valve |
| Check valve leaking | Take compressor to service center |
|
| DANGER: | |
|
| Do not disassemble check valve, | |
|
| tank drain valves or safety relief valve | |
|
| with air in tank — bleed tank. | |
|
|
|
|
|
|
|
|
Excessive moisture in discharge air | Excessive water in air tank | Drain tank | |
| High humidity | Move to area of less humidity; use air | |
|
| line filter | |
|
|
|
|
Compressor runs continuously | Defective pressure switch | Take compressor to service center | |
| Excessive air usage | Decrease air usage; compressor not | |
|
| large enough for tool’s requirement | |
|
|
|
|
Compressor vibrates | Loose mounting bolts | Tighten mounting bolts | |
|
|
|
|
Air output lower than normal | Broken inlet valves | Take compressor to service center | |
| Connections leaking | Tighten connections |
19