OPERATION

checking the Safety Valve

See Figure 12.

danger:

Do not attempt to tamper with the safety valve. Anything loosened from this device could fly up and hit you. Failure to heed this warning could result in death or serious personal injury.

The safety valve will automatically release air if the air tank pressure exceeds the preset maximum. The valve should be checked before each day of use by pulling the ring by hand.

nTurn the air compressor on and allow the tanks to fill. The compressor will shut off when the pressure reaches the preset maximum.

nTurn the air compressor off.

nPull the ring on the safety valve to release air for three to five seconds.

nRelease the ring. Air must immediately stop escaping when the ring is released. Any continued loss of air after releasing the safety valve ring indicates a problem with the safety valve. Discontinue use and seek service before continued use of the air compressor.

warning:

If air leaks after the ring has been released, or if the valve is stuck and cannot be actuated by the ring. Do not use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could result in serious personal injury.

SAFETY VALVE

ON

OFF

O

 

I

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

18,8Gallon

 

 

 

 

 

 

 

 

18,7

Litre

 

 

 

 

 

4.

 

 

 

 

Litro

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

mSCFM3

 

 

 

 

 

 

 

 

0,12

 

 

 

 

 

 

 

 

 

 

 

0,12

 

 

 

@

 

 

 

 

 

m3/Min

 

 

 

90PSI

 

 

 

 

 

 

 

/Min

@

 

 

 

 

 

 

 

 

@621

 

 

 

 

 

 

 

 

 

 

 

6,21 kPa

 

 

 

 

 

145

Max

 

 

 

bar

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

999

 

 

PSI

 

 

 

 

 

 

9,99KpA

OIL

WHEELBARROW

 

 

 

 

bar

 

 

 

 

 

 

 

 

 

 

 

 

 

LUBE

 

 

 

 

 

 

 

 

 

 

 

 

PUMP-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

POMPEA

 

 

 

 

 

 

 

 

 

 

 

HULE-

 

 

 

 

 

 

 

 

 

 

 

2

BOMBA

 

 

 

 

 

 

 

 

 

 

 

 

TO RELEASE AIR

RING

Fig. 12

 

RESET

BUTTON

Fig. 13

ReSET BUTTON

See Figure 13.

When amperage into the air compressor exceeds the specified amperage, the air compressor will automatically shut off.

To reset the air compressor:

nTurn the air compressor off.

nUnplug the air compressor for 30 minutes.

NOTE: If the overload protector is actuated, the motor must be allowed to cool down for 30 minutes before manual resetting.

nPress the reset button.

nPlug the air compressor into an approved outlet.

nTurn the air compressor on.

14

Page 14
Image 14
RIDGID OL50145MW Checking the Safety Valve, ReSET Button, To Release AIR Ring Reset Button, To reset the air compressor

OL50145MW specifications

The RIDGID OL50145MW is a versatile and efficient multi-wattage LED work light designed to provide high-quality illumination for various applications. Ideal for both professional contractors and DIY enthusiasts, this work light combines advanced technology with exceptional durability, making it a reliable choice for any job site or workspace.

One of the standout features of the OL50145MW is its adjustable brightness settings. With multiple wattage options, users can customize the light output according to their specific needs. This flexibility allows for optimal lighting in different environments, whether you require a dim light for close-up tasks or a brighter setting for expansive areas. The LED technology used in this work light provides bright, clear illumination while consuming significantly less energy than traditional lighting solutions.

In addition to its adjustable brightness, the OL50145MW is built with a rugged, durable design that ensures it can withstand harsh working conditions. It is IP54 rated for water and dust resistance, making it suitable for outdoor use and challenging indoor environments. The body is constructed from impact-resistant materials, providing protection against drops and bumps, which enhances its longevity.

Another notable characteristic of the RIDGID OL50145MW is its portability. The light features a lightweight design and a convenient carrying handle, allowing users to easily transport it from one location to another. Moreover, it can be easily positioned due to its adjustable stand, providing versatile mounting options according to the task at hand.

For added convenience, the OL50145MW features an integrated hook that allows it to be hung in various locations, maximizing workspace lighting without requiring additional equipment. This is particularly advantageous for hands-free use when working in tight or elevated spaces.

Overall, the RIDGID OL50145MW stands as an exemplary solution for those seeking a reliable, high-performance work light. Its combination of advanced LED technology, customizable brightness settings, durable construction, and portability makes it a valuable tool for a wide range of applications. Whether you are on a construction site, working on home improvement projects, or need reliable lighting for automotive tasks, the OL50145MW is designed to meet the challenges of any job. With RIDGID’s commitment to quality and innovation, this work light proves itself to be an essential addition to any toolkit.