Rinnai Optional Equipment, Nomenclature, Heating Capacities, 37AHB Series Hydronic Furnace

Models: 37AHB

1 6
Download 6 pages 56.75 Kb
Page 3
Image 3
Optional Equipment
Connect an auxiliary 2.5 FLA, 2.5 LRA @ 115 VAC max Humidifier. Connections are made via the “HUM” quick connects. The humidifier output is on whenever a heating demand is being satisfied. The contacts of this output are isolated to allow application of 24 VAC or 115 VAC to one terminal and the humidifier load to the other.
Connect an auxiliary Electronic Air Cleaner; rating shall be max 1.0 Amp @ 115 VAC. This output is energized whenever any of the four blower speeds are energized. Connections are made via 0.250 x 0.032” male quick connect terminals labeled "EAC" and "N3".
Connect an auxiliary UV lamp (if required); rating shall be max 1.0 Amp @ 115 VAC. This output is energized whenever any of the four blower speeds are energized. Connections are made via 0.250 x 0.032” male quick connect terminals labeled "UV" and "N2".
Can accomodate most brands of evaporator A-coil for cooling applications.

37AHB Series Hydronic Furnace

Optional Equipment

FIELD-SUPPLIED ACCESSORIES capable of interfacing with the Rinnai Hydronic Furnace:

Humidifier (HUM)

Electronic Air Cleaner (EAC)

UV Lamp

Cooling Coil

Nomenclature

 

Model

37AH B

045 08 K

A 5

 

 

Multi-position

 

 

 

 

 

 

 

 

 

37AH - Multi-speed Hydronic Furnace

 

 

 

 

 

5 = Yes

 

Series

 

 

 

 

 

 

 

2 = No

 

 

 

 

 

 

 

 

 

 

 

A - Unit with PSC Motor

 

 

 

 

 

Engineering Digit

 

B - Unit with ECM Technology

 

 

 

 

 

Denotes minor change

 

 

 

 

 

 

 

 

 

 

 

Nominal Heating Capacity (BTU/h)

 

 

 

Voltage Code (V-Ph-HZ)

045 = 45,000

 

 

 

 

Cooling / Heating

 

 

 

 

 

 

K = 115 - 1 - 60

060 = 60,000

 

 

 

 

 

 

 

 

 

Air Flow Range (CFM)

 

 

 

 

L = 240 - 1 - 50 (export models)

075 = 75,000

 

 

 

 

08 = 800 (650-800)

 

 

 

 

 

 

 

 

 

 

090 = 90,000

 

 

 

 

 

 

 

 

 

 

 

 

 

12 = 1200 (650-1200)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14 = 1400 (1000-1600)

 

 

 

 

 

 

 

 

 

 

 

16 = 1600 (1200-1750)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating Capacities

 

 

Nominal heating capacities as tested with Rinnai tankless water heaters.

 

 

 

 

 

For final rated capacities refer to the Air Delivery and Performance

 

 

 

 

 

 

 

 

 

 

Tables in the Operation and Installation Manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AHB45 (BTU)

 

AHB60 (BTU)

 

AHB75 (BTU)

 

AHB90 (BTU)

 

 

 

120º F

 

27,700

 

36,400

 

43,700

 

 

54,900

 

 

 

130º F

 

33,300

 

45,100

 

52,900

 

 

63,900

 

 

 

140º F

 

40,100

 

50,800

 

61,600

 

 

76,200

 

 

 

150º F

 

47,700

 

59,700

 

70,400

 

 

86,600

 

 

 

160º F

 

51,200

 

68,100

 

78,900

 

 

96,300

 

Page 3
Image 3
Rinnai Optional Equipment, Nomenclature, Heating Capacities, 37AHB Series Hydronic Furnace, 37AH B, 045 08 K