Rinnai R98EASME manual R98eASME V3237W-ASME, Type of Appliance Rinnai model number Operation

Models: R98EASME

1 2
Download 2 pages 51.84 Kb
Page 1
Image 1
Type of Appliance Rinnai model number Operation

R

Type of Appliance Rinnai model number Operation

Minimum/Maximum Gas Rate (Input) Electrical

Electrical Consumption

Ignition System Hot Water Capacity Temperature

Temperature (without controller) Approved Gas Types Installation

Thermal Efficiency

Service Connections

Water Flow Control

Minimum/Maximum Water Supply Pressure

R98eASME (V3237W-ASME)

This model has been built in accordance with the requirements of the ASME Boiler and Pressure Vessel Code and has received the Certificate of Authorization from the National Board. The heat exchanger has the NB and the HLW stamps.

Temperature controlled, continuous flow, gas hot water system REU-V3237W-ASME

Forced combustion

19,000 - 237,000 BTU/h (Natural Gas or Propane)

Appliance:

AC 120 Volts - 60 Hz

Controller:

DC 12 Volts

Normal

72 watts

Standby

2 watts

Anti-frost protection

116 watts

Direct electronic ignition

 

0.6 to 8.0 GPM (50° F rise)

0.9 to 9.8 GPM (35° F rise)

98° - 140° F

 

120° F (factory default)

 

Natural or Propane (ensure unit matches gas type)

Outdoor only

 

Natural Gas: 85%

Propane: 83%

Gas supply: 3/4 inch MNPT

Cold water inlet: 3/4 inch MNPT

Hot water outlet: 3/4 inch MNPT

Water flow sensor, electronic water control and by-pass control

15 - 150 PSI (50 PSI or above is recommended for maximum flow)

FLOW TABLE

Water Flow Capacity Curve

© 2008 Rinnai Corporation

3237W-ASME SP-1

4/2008

Page 1
Image 1
Rinnai R98EASME manual R98eASME V3237W-ASME, Type of Appliance Rinnai model number Operation, Electrical Consumption