![Water Temperature Control](/images/new-backgrounds/38327/383273x1.webp)
Water Temperature Control
Controller
Controller Cable
Safety Devices
Clearances from combustibles
Clearances from non-combustibles
* 24 inches required for serviceability
Min. / Max. Gas Supply Pressure
Manifold Gas Pressure (inches W.C.)
NOx
Warranty
R98eASME
Simulation feed forward and feedback
Deluxe controller:
Bathroom controller:
Wireless controller (with transceiver):
• | Flame failure - Flame Rod | • | Remaining flame (OHS) |
• | Boiling protection | • | Thermal fuse |
• | Combustion fan rpm check | • | Automatic frost protection |
•Over current - glass fuse (3 amp)
• Top of heater - 12 inches |
| • Back of heater - 0 inches | ||
• | Front (Panel) - 24 inches |
| • Bottom of heater - 12 inches | |
• | Front (Exhaust) - 24 inches | • Sides of heater - 6 inches | ||
• Top of heater - 2 inches |
| • Back of heater - 0 inches | ||
• Front (Panel) - 0 inches * |
| • Bottom of heater - 2 inches | ||
• | Front (Exhaust) - 24 inches | • Sides of heater - 1/8 inch | ||
Natural Gas: | min 5” W.C. |
| max 10.5” W.C. | |
Propane Gas: | min 8” W.C. |
| max 13.5” W.C. | |
Natural Gas: | high fire 3.0” | W.C. low fire 0.67” W.C. | ||
Propane Gas: | high fire 3.7” | W.C. | low fire 0.83” W.C. |
Meets California and Texas NOx Emission Rules
Residential only; heat exchanger 10 years*; all other parts 5 years*; labor 1 year; (* 3 years if used as a circulating water heater within a circulation loop, where the water heater is in series with a circulation system and all circulating water flows through the water heater, and where
Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation.
DIMENSIONS |
|
| WEIGHT: 55 LBS |
|
|
|
|
|
|
|
|
Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 •